Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
27030218 - PP-RJ-SC-F DIN Rail Patch Panel with surge protection: 1 x RJ45 socket, 1 x screw terminal block, 10/100/1000 Mbps, I by PERLE

27030218 - PP-RJ-SC-F DIN Rail Patch Panel with surge protection: 1 x RJ45 socket, 1 x screw terminal block, 10/100/1000 Mbps, I
by PERLE

Write a review Write a review
  • 10/100/1000 Mbps
  • RJ45 to RJ45, IDC, Push-in or Screw Terminal Block
  • Wiring space covered with front panel cover
  • Tool-free shield contacting with strain relief
  • Compact design with quick and easy mounting
  • Extended temperature range of -40°C to +75°C
  • Integrated surge protection to ensure high system availability

 

 

 

 

Mfg SKU # : 27030218
List Price : $357.00
Our Price : $304.00
Stock : 3
Quantity :

Ethernet patch panels make the connection between field cabling and control cabinet cabling quick and easy. In environments vulnerable to voltage surges, a PP-RJ-F DIN Rail Patch Panel is ideal for installation inside control panels and distribution cabinets where one-to-one simplified connections need to be made in environments. A standard Ethernet patch cable is used between the patch panel and the control cabinet equipment, such as switches, PLCs and routers. Through ICD, Push-in, Screw or RJ45 connectors, field wiring is easily connected to the patch panel and protected inside a covered wiring space. The cable shielding is connected quickly and easily, without tools, while simultaneously ensuring strain relief. This simplifies installation of the field cable and saves a great deal of time during installation. PP-RJ DIN Rail Patch Panels provide the perfect mix of density and flexibility to decrease network risk and improve cable organization in scalable deployments with constricted spaces.

Ideal applications for PP-RJ-F DIN Rail Patch Panels

  • Inside equipment cabinets with DIN rails
  • Alongside Industrial Ethernet switches and RJ45 (Ethernet or Serial) PLCs
  • Alongside other DIN Rail RJ45 (Ethernet or Serial) control devices
  • Where growth from one to many ports is needed to support high-density installations. Multiple one port DIN Rail Patch Panels can installed side-by-side to grow, as required by the customer application.

Benefits of PP-RJ-F DIN Rail Patch Panels

Integrated Surge Protection The integrated surge protection protects the devices and the application against sudden high voltages in the field data cables.
Shield current monitoring The cable shield current monitoring can be used for diagnostics. An LED indicates if there are differences in potential or other shield currents caused by EMC.

Shield Current Monitoring LED
Multiple connection technologies For greater flexibility and time savings during installation you can choose between IDC, Push-in, Screw, and RJ45 connections.
  • RJ45 – standard RJ45 Ethernet type connector
  • IDC Terminal Block – due to the tool used, it offers increased productivity and security
  • Push-in Terminal Block – wires can be pushed-in, no tool required
  • Screw Terminal Block – used for tight connections
Covered cable wiring space A hinged cover protects the wiring space on the field cable side with connection terminal blocks and shield contacting. This ensures a uniform installation pattern. In addition to this visual extra, the sensitive connection wires are protected from external influences.
Quick tool-free shield connection with no loose parts The cable shielding can be connected to the device quickly and easily without tools – with strain relief assured at the same time. Simply lay the cable in the shaft provided, close the shroud and, you're done.

Tool-free shield connection
DIN Rail Enclosure Easily mount on a DIN rail or inside distribution boxes using native DIN Rail enclosure with grounding clip. No need for add-on brackets.
Low profile design The low-profile design minimizes cable bend radius in shallow enclosures where space is a premium as well as providing secure cable strain relief.
Serial interface
Interface 1 Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u
Connection method Screw terminal block
Transmission length 100 m (including patch cables)
Pin assignment 1:1
Serial transmission speed 10/100/1000 Mbps
Maximum output current 725 mA (PoE)
Current carrying capacity ≤ 1.5 A (≤ 60 W (PoE+))
Maximum output power 60 W
Interface 2 Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u
Connection method RJ45 CAT5e
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 28
Conductor cross section AWG max. 16
Torque 0.22 Nm ... 0.25 Nm
Stripping length 5 mm
Wire diameter incl. insulation
Ambient conditions
Ambient temperature (operation) -40°C ... 75°C
Ambient temperature (storage/transport) -40°C ... 85°C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Altitude 5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval)
Degree of protection IP20 (Manufacturer's declaration)
General
Electrical isolation FE // Ethernet
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Net weight 124.2 g
Housing material Plastic
Color Gray
MTTF 3268 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
1238 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day))
468 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Degree of pollution 2
Overvoltage category II
Conformance CE-compliant
ATEX  II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 / Class I, Div. 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Standards and Regulations
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 30g for 11 ms, three shocks in each spatial direction
Type of test Continuous shock according to EN 60068-2-27/IEC 60068-2-27
Test result 10g for 16 ms, 1000 shocks in each spatial direction
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV (Test Level 3)
Indirect discharge ± 6 kV
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 3 GHz (Test Level 3)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal ± 1 kV (Data line, asymmetrical)
Standards/regulations EN 61000-6-4 / EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Standards/regulations DIN EN 61643-21
Rated insulation voltage 85 V DC
IEC test classification C2
Conformance CE-compliant
ATEX  II 3 G Ex nA nC IIC T4 Gc X
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 / Class I, Div. 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Noxious gas test ISA-S71.04-1985 G3 Harsh Group A
Function
Designation Shield current monitoring
Switch-on threshold ≥ 30 mA
Local diagnostics Yellow LED
Precision ± 5 %
Response time 3 s
Continuous shield current ≤ 1.5 A
Power consumption 270 mW (Shield current monitoring)
Impedance ≤ 1 Ω
Voltage ≤ 10 V
Dimensions
Width 23.8 mm
Height 101.3 mm
Depth 86 mm
Note
Utilization restriction 1
Power supply
Supply voltage range 36 V DC ... 52 V DC 10 % (via PoE (for shield current monitoring)) 36 V DC ... 52 V DC 10 % (via PoE)
42 V DC ... 57 V DC (With UL approval)
Approvals
  • cULus Listed
  • cUL Listed
  • UL Listed
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
REACH SVHC Lead 7439-92-1

Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.