ES1500C-RM - 980W 1400VA Enhanced Series 8-Outlet Line Interactive Uninterruptible Power Supply by OPTI-UPS
|
|
|
- AVR (automatic voltage regulator)
- 8 battery backup outlets
- RJ11/RJ45 protection
- 2U design
- Easy battery replacement procedure
- 1050 Joules energy rating
- 4 hours battery recharge time
- Transfer time 4 ms
- LED display- Shows UPS operating status
- Surge Protection
- Auto-Start after AC utility return
- Communication port RS232
- High Power Factor
- Advance Warning-Front Panel: AC Mode/Buck/Boost/Battery Mode/ Battery Fault
- Advance Warning-Audible Alarms: Battery Mode/ Overload
- Supports OPTI-SAFE Sentinel Microsoft Windows 98, Windows 7, Windows 8, Windows 2000, Windows XP, Windows Vista, Windows Server 2003 and Windows Server 2008
|
|
|
ESC-RM series offer the highest power capacity and the best equipment protection around. Not only do they protect against blackouts, sags and surges, but with the added feature of AVR (Automatic Voltage Regulator), these UPS products ensure that only clean and safe currents reach your equipment.
What is AVR?
AVR is a feature that corrects under and over voltages without draining the battery, thus providing extended battery life and, most important, allowing the UPS to provide high quality power during unacceptable voltage fluctuations.
MODEL NAME |
ES1500C-RM |
Topology |
Line-Interactive |
On-battery Output Waveform |
Step Wave |
INPUT |
Maximum Capacity |
1400VA / 980W |
Nominal Input Voltage |
110/120V(!!) |
Input Frequency |
50/60Hz Auto sensing |
AC Line-In Plug |
110/120V models |
NEMA 5-15P |

|
OUTPUT |
Nominal Output Voltage |
110/120Vac(!!) |
Output Voltage Regulation |
Rated Voltage +/- 5% |
Transfer Time |
4 ms (typical) |
Overload Protection |
Circuit Breaker |
Type and Number of Outlets |
110/120V models |
NEMA 5-15R
8 x Battery Backup |

|
PROTECTION |
Automatic Voltage Regulation (AVR) |
Yes |
Data Line Protection |
RJ11 / RJ45 |
Surge Energy Rating |
1050 Joules |
Normal Mode Noise Suppression |
Full time EMI/RFI filtering |
USER REPLACEABLE BATTERY |
User Replaceable Battery |
RBAT-92 |
Typical Back-up Time (1PC + 1 CRT)1) |
65 ~ 75 min |
Full load runtime |
2 Minutes (1300VA) |
Half load runtime |
6 Minutes (800VA) |
Typical Recharge Time to 90% |
<4 Hours |
MONITORING |
Front Panel LEDs |
AC mode, Battery mode, Battery fault, Buck Mode, Boost Mode, Overload |
Audible Alarms |
Battery mode, UPS fault, Overload |
COMMUNICATION INTERFACE |
Communication Port |
RS232 or USB2) |
ENVIRONMENTAL PARAMETERS |
Operating Temperature |
0°C~40°C / 32°F~104°F |
Storage Temperature |
-20°C~60°C / -4°F~140°F |
Audible Noise |
< 40 dBA |
PHYSICAL PARAMETERS |
Dimensions (LxWxH) |
Physical |
16.8x16.9x3.3 inch / 426x428x84 mm |
Packing |
21.9x21.7x8.1 inch / 555x550x205 mm |
Weight |
Net |
39.1lb / 17.7kg |
Gross |
45.8 lb / 20.8 kg |
|
|