Environmental Product Compliance |
REACH SVHC |
Lead 7439-92-1 |
China RoHS |
Environmentally Friendly Use Period = 25; |
General |
Net weight |
1.5 kg |
Efficiency |
> 90 % (for 230 V AC and nominal values) |
Insulation voltage input/output |
4 kV AC (type test) |
|
2 kV AC (routine test) |
Insulation voltage input / PE |
3.5 kV AC (type test) |
|
2 kV AC (routine test) |
Insulation voltage output / PE |
500 V DC (routine test) |
Protection class |
I |
Degree of protection |
IP20 |
MTBF (IEC 61709, SN 29500) |
> 1000000 h (25 °C) |
|
> 600000 h (40 °C) |
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
Assembly instructions |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Standards and Regulations |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Noise emission |
EN 55011 (EN 55022) |
Noise immunity |
EN 61000-6-2:2005 |
Connection in acc. with standard |
CSA |
Standards/regulations |
EN 61000-4-2 |
Contact discharge |
4 kV (Test Level 2) |
Standards/regulations |
EN 61000-4-3 |
Frequency range |
80 MHz ... 1 GHz |
Test field strength |
10 V/m (Test Level 3) |
Frequency range |
1.4 GHz ... 2 GHz |
Test field strength |
3 V/m (Test Level 2) |
Standards/regulations |
EN 61000-4-4 |
Comments |
Criterion B |
Standards/regulations |
EN 61000-6-3 |
|
EN 61000-4-6 |
Frequency range |
0.15 MHz ... 80 MHz |
Voltage |
10 V (Test Level 3) |
Low Voltage Directive |
Conformance with LV directive 2006/95/EC |
Standard - Electrical safety |
IEC 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation |
DIN VDE 0100-410 |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
Standard - Equipment safety |
GS (tested safety) |
Standard - Approval for medical use |
IEC 60601-1, 2 x MOOP |
UL approvals |
UL Listed UL 508 |
|
UL/C-UL Recognized UL 60950-1 |
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
|
15 Hz ... 150 Hz, 2.3g, 90 min. |
Information technology equipment - safety (CB scheme) |
CB Scheme |
Rail applications |
EN 50121-4 |
Overvoltage category (EN 62477-1) |
III |
Connection data, input |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Conductor cross section AWG min. |
18 |
Conductor cross section AWG max. |
10 |
Stripping length |
7 mm |
Screw thread |
M3 |
Output data |
Nominal output voltage |
12 V DC ±1 % |
Setting range of the output voltage (USet) |
5 V DC ... 18 V DC (> 12 V DC, constant capacity restricted) |
Nominal output current (IN) |
20 A (-25 °C ... 60 °C) |
POWER BOOST (IBoost) |
26 A (-25°C ... 40°C permanent ) |
Selective Fuse Breaking (ISFB) |
120 A (12 ms) |
Derating |
60 °C ... 70 °C (2.5%/K) |
Connection in parallel |
Yes, for redundancy and increased capacity |
Connection in series |
yes |
Feedback resistance |
max. 25 V DC |
Protection against surge voltage on the output |
< 25 V DC |
Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
|
< 2 % (change in load, dynamic 10 % ... 90 %) |
|
< 0.1 % (change in input voltage ±10 %) |
Residual ripple |
< 50 mVPP (with nominal values) |
Output power |
240 W |
Typical response time |
< 1 s |
Maximum power dissipation in no-load condition |
6 W |
Power loss nominal load max. |
29 W |
Connection data for signaling |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Conductor cross section AWG min. |
18 |
Conductor cross section AWG max. |
10 |
Screw thread |
M3 |
Dimensions |
Width |
90 mm |
Height |
130 mm |
Depth |
125 mm |
Width with alternative assembly |
122 mm |
Height with alternative assembly |
130 mm |
Depth with alternative assembly |
93 mm |
Weight per piece |
1500.0 GRM |
Input data |
Nominal input voltage range |
100 V AC ... 240 V AC |
Input voltage range |
85 V AC ... 264 V AC |
|
90 V DC ... 350 V DC (UL 508: ≤ 250 V DC) |
Dielectric strength maximum |
300 V AC |
AC frequency range |
45 Hz ... 65 Hz |
Frequency range DC |
0 Hz |
Discharge current to PE |
< 3.5 mA |
Current consumption |
2.4 A (120 V AC) |
|
1.4 A (230 V AC) |
|
2.5 A (110 V DC) |
|
1.2 A (220 V DC) |
Nominal power consumption |
311 VA |
Inrush surge current |
< 20 A (typical) |
Mains buffering |
typ. 40 ms (120 V AC) |
|
typ. 40 ms (230 V AC) |
Input fuse |
12 A (slow-blow, internal) |
Choice of suitable circuit breakers |
10 A ... 16 A (AC: Characteristics B, C, D, K) |
Type of protection |
Transient surge protection |
Protective circuit/component |
Varistor |
Connection data, onput |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Conductor cross section AWG min. |
12 |
Conductor cross section AWG max. |
10 |
Stripping length |
7 mm |
Screw thread |
M3 |
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) |
-40 °C |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Max. permissible relative humidity (operation) |
95 % (at 25 °C, non-condensing) |
Climatic class |
3K3 (in acc. with EN 60721) |
Degree of pollution |
2 |
Installation height |
6000 m |
Approvals |
|
- cULus Listed
- cULus Recognized
- EAC
- UL Recognized
- CSA
- SEMI F47
- cUL Recognized
- cUL Listed
- IECEE CB Scheme
- UL Listed
|