23208278 |
28668028 |
29046218 |
29046228 |
Environmental Product Compliance |
REACH SVHC |
Lead 7439-92-1 |
Lead 7439-92-1 |
Lead 7439-92-1 |
Lead 7439-92-1 |
China RoHS |
Environmentally Friendly Use Period = 25; |
Environmentally Friendly Use Period = 25; |
Environmentally Friendly Use Period = 25; |
Environmentally Friendly Use Period = 25; |
General |
Net weight |
2.5 kg |
2.5 kg |
0.9 kg |
1.1 kg |
Efficiency |
> 93 % (at 400 V AC and nominal values) |
> 94 % (at 400 V AC and nominal values) |
typ. 93 % (400 V AC) |
typ. 93.9 % (400 V AC) |
Insulation voltage input/output |
4 kV AC (type test) |
4 kV AC (type test) |
4 kV AC (type test) |
4 kV AC (type test) |
|
2 kV AC (routine test) |
2 kV AC (routine test) |
2.4 kV AC (routine test) |
2.4 kV AC (routine test) |
Insulation voltage input / PE |
3.5 kV AC (type test) |
3.5 kV AC (type test) |
3.5 kV AC (type test) |
3.5 kV AC (type test) |
|
2 kV AC (routine test) |
2 kV AC (routine test) |
2.4 kV AC (routine test) |
2.4 kV AC (routine test) |
Insulation voltage output / PE |
500 V DC (routine test) |
500 V DC (routine test) |
0.5 kV DC (type test) |
0.5 kV DC (type test) |
Protection class |
I |
I |
I |
I |
Degree of protection |
IP20 |
IP20 |
IP20 |
IP20 |
MTBF (IEC 61709, SN 29500) |
889679,72 h (25 °C) |
> 880000 h (25 °C) |
> 1034000 h (25 °C) |
> 985000 h (25 °C) |
|
501504,51 h (40 °C) |
> 500000 h (40 °C) |
> 654000 h (40 °C) |
> 638000 h (40 °C) |
|
216825,67 h (60 °C) |
> 216000 s (60 °C) |
> 320000 h (60 °C) |
> 311000 h (60 °C) |
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
horizontal DIN rail NS 35, EN 60715 |
horizontal DIN rail NS 35, EN 60715 |
horizontal DIN rail NS 35, EN 60715 |
Assembly instructions |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Operating voltage display |
|
Green LED |
|
|
Efficiency |
|
|
typ. 92.6 % (480 V AC) |
typ. 93.8 % (480 V AC) |
Insulation voltage output / PE |
|
|
0.5 kV DC (routine test) |
0.5 kV DC (routine test) |
Standards and Regulations |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Conformance with EMC Directive 2014/30/EU |
Conformance with EMC Directive 2014/30/EU |
Conformance with EMC Directive 2014/30/EU |
Noise immunity |
EN 61000-6-2:2005 |
EN 61000-6-2:2005 |
Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply) |
Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply) |
Connection in acc. with standard |
CSA |
CSA |
|
|
Standards/regulations |
EN 61000-4-2 |
EN 61000-4-2 |
EN 61000-4-2 |
EN 61000-4-2 |
Contact discharge |
4 kV (Test Level 2) |
4 kV (Test Level 2) |
4 kV (Test Level 2) |
4 kV (Test Level 2) |
Standards/regulations |
EN 61000-4-3 |
EN 61000-4-3 |
EN 61000-4-3 |
EN 61000-4-3 |
Frequency range |
80 MHz ... 1 GHz |
80 MHz ... 1 GHz |
80 MHz ... 1 GHz |
80 MHz ... 1 GHz |
Test field strength |
10 V/m (Test Level 3) |
10 V/m (Test Level 3) |
10 V/m (Test Level 3) |
10 V/m (Test Level 3) |
Frequency range |
1.4 GHz ... 2 GHz |
1.4 GHz ... 2 GHz |
1.4 GHz ... 2 GHz |
1.4 GHz ... 2 GHz |
Test field strength |
3 V/m (Test Level 2) |
3 V/m (Test Level 2) |
3 V/m (Test Level 2) |
3 V/m (Test Level 2) |
Standards/regulations |
EN 61000-4-4 |
EN 61000-4-4 |
EN 61000-4-4 |
EN 61000-4-4 |
Comments |
Criterion B |
Criterion B |
Criterion B |
Criterion B |
Standards/regulations |
EN 61000-4-6 |
EN 61000-6-3 |
EN 61000-4-6 |
EN 61000-4-6 |
Frequency range |
0.15 MHz ... 80 MHz |
0.15 MHz ... 80 MHz |
0.15 MHz ... 80 MHz |
0.15 MHz ... 80 MHz |
Voltage |
10 V (Test Level 3) |
10 V (Test Level 3) |
10 V (Test Level 3) |
10 V (Test Level 3) |
Low Voltage Directive |
Conformance with LV directive 2006/95/EC |
Conformance with LV directive 2006/95/EC |
Conformance with Low Voltage Directive 2014/35/EC |
Conformance with Low Voltage Directive 2014/35/EC |
Standard - Safety of transformers |
IEC 61558-2-17 |
|
EN 61558-2-16 (air clearances and creepage distances only) |
EN 61558-2-16 (air clearances and creepage distances only) |
Standard - Electrical safety |
IEC 60950-1/VDE 0805 (SELV) |
IEC 60950-1/VDE 0805 (SELV) |
IEC 60950-1/VDE 0805 (SELV) |
IEC 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
EN 50178/VDE 0160 (PELV) / Overvoltage category III |
EN 50178/VDE 0160 (PELV) |
EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation |
DIN VDE 0100-410 |
DIN VDE 0100-410 |
DIN VDE 0100-410 |
DIN VDE 0100-410 |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
|
|
|
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
EN 61000-3-2 |
EN 61000-3-2 |
EN 61000-3-2 |
Standard - Equipment safety |
BG (design tested) |
GS (tested safety) |
|
|
Standard - Approval for medical use |
IEC 60601-1, 2 x MOOP |
|
|
|
UL approvals |
UL Listed UL 508 |
UL Listed UL 508 |
UL Listed UL 508 |
UL Listed UL 508 |
|
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) |
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) |
UL/C-UL Recognized UL 60950-1 |
UL/C-UL Recognized UL 60950-1 |
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) |
5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) |
5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) |
|
15 Hz ... 150 Hz, 2.3g, 90 min. |
|
|
|
Information technology equipment - safety (CB scheme) |
CB Scheme |
CB Scheme |
|
|
Rail applications |
EN 50121-4 |
EN 50121-4 |
EN 50121-3-2 |
EN 50121-3-2 |
Overvoltage category (EN 62477-1) |
III |
III |
III (≤ 2000 m) |
III (≤ 2000 m) |
Standards/regulations |
|
EN 61000-4-6 |
EN 61000-4-8 |
EN 61000-4-8 |
Standard - Safe isolation |
|
DIN VDE 0106-101 |
|
|
Shipbuilding approval |
|
DNV GL (EMC A), ABS, LR, RINA, NK, BV |
DNV GL, PRS, BV, LR, ABS |
DNV GL, PRS, BV, LR, ABS |
Noise emission |
|
|
Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) |
Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) |
Conducted noise emission |
|
|
EN 55016 EN 61000-6-4 (Class A) |
EN 55016 EN 61000-6-4 (Class A) |
Standards/regulations |
|
|
EN 61000-4-11 |
EN 61000-4-11 |
|
|
|
EN 61000-4-9 |
EN 61000-4-9 |
|
|
|
EN 61000-4-12 |
EN 61000-4-12 |
|
|
|
EN 61000-4-16 |
EN 61000-4-16 |
|
|
|
EN 61000-4-18 |
EN 61000-4-18 |
Standard - power supply devices for low voltage with DC output |
|
|
EN 61204-3 |
EN 61204-3 |
EMC requirements, power plant |
|
|
IEC 61850-3 |
|
|
|
|
EN 61000-6-5 |
|
Approval - requirement of the semiconductor industry with regard to mains voltage dips |
|
|
SEMI F47-0706; EN 61000-4-11 |
SEMI F47-0706; EN 61000-4-11 |
Overvoltage category (EN 60950-1) |
|
|
II (≤ 5000 m) |
II (≤ 5000 m) |
Overvoltage category (EN 61010-1) |
|
|
II (≤ 5000 m) |
II (≤ 5000 m) |
Connection data, input |
Connection method |
Screw connection |
Screw connection |
Screw connection |
Screw connection |
Conductor cross section solid min. |
0.2 mm² |
0.2 mm² |
0.2 mm² |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
6 mm² |
6 mm² |
6 mm² |
Conductor cross section flexible min. |
0.2 mm² |
0.2 mm² |
0.2 mm² |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
4 mm² |
4 mm² |
4 mm² |
Conductor cross section AWG min. |
18 |
18 |
30 |
30 |
Conductor cross section AWG max. |
10 |
10 |
10 |
10 |
Stripping length |
7 mm |
7 mm |
8 mm |
8 mm |
Screw thread |
M3 |
M3 |
|
|
Output data |
Nominal output voltage |
48 V DC ±1 % |
24 V DC ±1 % |
24 V DC |
24 V DC |
Setting range of the output voltage (USet) |
30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted) |
18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) |
24 V DC ... 29.5 V DC (constant capacity) |
24 V DC ... 29.5 V DC (constant capacity) |
Nominal output current (IN) |
20 A (-25 °C ... 60 °C, UOUT = 48 V DC) |
40 A (-25 °C ... 60 °C, UOUT = 24 V DC) |
10 A |
20 A |
POWER BOOST (IBoost) |
22.5 A (-25°C ... 40°C permanent, UOUT = 48 V DC ) |
45 A (-25°C ... 40°C permanent, UOUT = 24 V DC ) |
|
|
Selective Fuse Breaking (ISFB) |
100 A (12 ms) |
215 A (12 ms) |
60 A (15 ms) |
120 A (15 ms) |
Derating |
60 °C ... 70 °C (2.5%/K) |
60 °C ... 70 °C (2.5%/K) |
> 60 °C (2.5%/K) |
> 60 °C (2.5%/K) |
Connection in parallel |
Yes, for redundancy and increased capacity |
Yes, for redundancy and increased capacity |
Yes, for redundancy and increased capacity |
Yes, for redundancy and increased capacity |
Connection in series |
yes |
yes |
yes |
yes |
Feedback resistance |
max. 60 V DC |
max. 35 V DC |
≤ 35 V DC |
≤ 35 V DC |
Protection against surge voltage on the output |
< 60 V DC |
< 35 V DC |
≤ 32 V DC |
≤ 32 V DC |
Active current limitation |
Approx. IBOOST = 22.5 A (for short-circuit) |
|
|
|
Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
< 1 % (change in load, static 10 % ... 90 %) |
< 0.5 % (Static load change 10 % ... 90 %) |
< 0.5 % (Static load change 10 % ... 90 %) |
|
< 4 % (change in load, dynamic 10 % ... 90 %) |
< 3 % (change in load, dynamic 10 % ... 90 %) |
< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz)) |
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz)) |
|
< 0.1 % (change in input voltage ±10 %) |
< 0.1 % (change in input voltage ±10 %) |
< 0.25 % (change in input voltage ±10 %) |
< 0.25 % (change in input voltage ±10 %) |
Residual ripple |
< 50 mVPP (with nominal values) |
< 40 mVPP (with nominal values) |
< 75 mVPP (with nominal values) |
< 60 mVPP (with nominal values) |
Output power |
960 W |
960 W |
240 W |
480 W |
Typical response time |
< 1 s |
< 0.5 s |
300 ms (from SLEEP MODE) |
300 ms (from SLEEP MODE) |
Maximum power dissipation in no-load condition |
24 W |
18 W |
< 5 W (400 V AC) |
< 7 W (400 V AC) |
Power loss nominal load max. |
70 W |
63 W |
< 19 W (400 V AC) |
< 32 W (400 V AC) |
Peak switching voltages nominal load |
|
< 5 mVPP (at nominal values, 20 MHz) |
|
|
Static Boost (IStat.Boost) |
|
|
12.5 A |
25 A |
Dynamic Boost (IDyn.Boost) |
|
|
20 A (5 s) |
30 A (5 s) |
Maximum power dissipation in no-load condition |
|
|
< 5 W (480 V AC) |
< 7 W (480 V AC) |
Power loss nominal load max. |
|
|
< 20 W (480 V AC) |
< 33 W (480 V AC) |
Connection data for signaling |
Conductor cross section solid min. |
0.2 mm² |
0.2 mm² |
0.2 mm² |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
6 mm² |
1.5 mm² |
1.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
0.2 mm² |
0.2 mm² |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
4 mm² |
1.5 mm² |
1.5 mm² |
Conductor cross section AWG min. |
18 |
18 |
24 |
24 |
Conductor cross section AWG max. |
10 |
10 |
16 |
16 |
Screw thread |
M3 |
M3 |
|
|
Connection method |
|
|
Push-in connection |
Push-in connection |
Stripping length |
|
|
8 mm |
8 mm |
Dimensions |
Width |
96 mm |
96 mm |
50 mm |
70 mm |
Height |
130 mm |
130 mm |
130 mm |
130 mm |
Depth |
179 mm |
176 mm |
125 mm |
125 mm |
Width with alternative assembly |
176 mm |
176 mm |
122 mm |
122 mm |
Height with alternative assembly |
130 mm |
130 mm |
130 mm |
130 mm |
Depth with alternative assembly |
99 mm |
99 mm |
53 mm |
73 mm |
Weight per piece |
2500.0 GRM |
2954.0 GRM |
1000.0 GRM |
1516.8 GRM |
Input data |
Nominal input voltage range |
3x 400 V AC ... 500 V AC |
3x 400 V AC ... 500 V AC |
3x 400 V AC ... 500 V AC |
3x 400 V AC ... 500 V AC |
Input voltage range |
3x 320 V AC ... 575 V AC |
3x 320 V AC ... 575 V AC |
3x 400 V AC ... 500 V AC -20 % ... +10 % |
3x 400 V AC ... 500 V AC -20 % ... +10 % |
|
2x 360 V AC ... 575 V AC (Not approved by UL) |
2x 360 V AC ... 575 V AC |
2x 400 V AC ... 500 V AC -10 % ... +10 % |
2x 400 V AC ... 500 V AC -10 % ... +10 % |
|
450 V DC ... 800 V DC |
450 V DC ... 800 V DC |
± 260 V DC ... 300 V DC -13 % ... +30 % |
± 260 V DC ... 300 V DC -13 % ... +30 % |
AC frequency range |
45 Hz ... 65 Hz |
45 Hz ... 65 Hz |
50 Hz ... 60 Hz -10 % ... +10 % |
50 Hz ... 60 Hz -10 % ... +10 % |
Frequency range DC |
0 Hz |
0 Hz |
|
|
Discharge current to PE |
< 3.5 mA |
< 3.5 mA |
< 3.5 mA |
< 3.5 mA |
Current consumption |
3x 2.1 A (400 V AC) |
3x 2.1 A (400 V AC) |
3x 0.5 A (400 V AC) |
3x 0.99 A (400 V AC) |
|
3x 1.7 A (500 V AC) |
3x 1.7 A (500 V AC) |
3x 0.41 A (480 V AC) |
3x 0.81 A (480 V AC) |
|
1.7 A (600 V DC) |
1.7 A (600 V DC) |
2x 1.1 A (400 V AC) |
2x 1.62 A (400 V AC) |
Nominal power consumption |
1386 VA |
1342 VA |
274 VA |
541 VA |
Inrush surge current |
< 20 A (typical) |
< 15 A |
typ. 3 A (at 25 °C) |
typ. 2 A (at 25 °C) |
Mains buffering |
typ. 25 ms (400 V AC) |
> 25 ms (400 V AC) |
typ. 29 ms (3x 400 V AC) |
typ. 33 ms (3x 400 V AC) |
|
typ. 35 ms (500 V AC) |
> 35 ms (500 V AC) |
typ. 26 ms (3x 480 V AC) |
typ. 33 ms (3x 480 V AC) |
Choice of suitable circuit breakers |
6 A ... 16 A (AC: Characteristics B, C, D, K) |
6 A ... 16 A (AC: Characteristics B, C, D, K) |
3x 4 A ... 20 A (Characteristic B, C or comparable) |
3x 4 A ... 20 A (Characteristic B, C or comparable) |
Type of protection |
Transient surge protection |
Transient surge protection |
Transient surge protection |
Transient surge protection |
Protective circuit/component |
Varistor |
Varistor, gas-filled surge arrester |
Varistor, gas-filled surge arrester |
Varistor, gas-filled surge arrester |
Nominal input voltage range |
|
|
2x 400 V AC ... 500 V AC |
2x 400 V AC ... 500 V AC |
|
|
|
± 260 V DC ... 300 V DC |
± 260 V DC ... 300 V DC |
Current consumption |
|
|
2x 0.91 A (480 V AC) |
2x 1.37 A (480 V AC) |
|
|
|
3x 0.4 A (500 V AC) |
3x 0.8 A (500 V AC) |
|
|
|
2x 1.1 A (500 V AC) |
2x 1.23 A (500 V AC) |
Connection data, onput |
Conductor cross section solid min. |
0.2 mm² |
0.2 mm² |
0.2 mm² |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
6 mm² |
1.5 mm² |
1.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
0.2 mm² |
0.2 mm² |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
4 mm² |
1.5 mm² |
1.5 mm² |
Conductor cross section AWG min. |
18 |
18 |
24 |
24 |
Conductor cross section AWG max. |
10 |
10 |
16 |
16 |
Screw thread |
M3 |
M3 |
|
|
Connection method |
|
|
Push-in connection |
Push-in connection |
Stripping length |
|
|
8 mm |
8 mm |
Screw thread |
M3 |
M4 |
|
|
Ambient conditions |
Degree of protection |
IP20 |
IP20 |
IP20 |
IP20 |
Ambient temperature (operation) |
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) |
-40 °C |
-40 °C |
-40 °C |
-40 °C |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
-40 °C ... 85 °C |
-40 °C ... 85 °C |
-40 °C ... 85 °C |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
≤ 95 % (at 25 °C, non-condensing) |
≤ 95 % (at 25 °C, non-condensing) |
≤ 95 % (at 25 °C, non-condensing) |
Climatic class |
3K3 (in acc. with EN 60721) |
3K3 (in acc. with EN 60721) |
3K3 (in acc. with EN 60721) |
3K3 (in acc. with EN 60721) |
Degree of pollution |
2 |
2 |
2 |
2 |
Installation height |
4000 m |
4000 m |
≤ 5000 m (> 2000 m, observe derating) |
≤ 5000 m (> 2000 m, observe derating) |
Approvals |
|
- ABS
- DNV GL
- BV
- cCSAus
- SEMI F47
- RINA
- cUL Recognized
- cUL Listed
- LR
- UL Listed
- IECEE CB Scheme
- cULus Listed
- UL Recognized
- EAC
- cULus Recognized
- NK
- CSA
- Bauartgeprüft
- CSAus
|