TN-4908-ETBN-4GTX-4GTXBP-WV-CT-T - 8*GE ETBN router with 4*GE BP port, 24-110 VDC power input, conformal coating -40 to 70oC, IP by MOXA
|
|
|
TN-4908-ETBN-4GTX-4GTXBP-WV-CT-T_SUMMARY.html
- 8 Gigabit ports and up to 12 PoE ports
- IEC 61375 ETBN functionality (ETBN models)
- Dual bypass relay
- Isolated power input range from 24 to 110 VDC
- Complies with all EN 50155 mandatory test items This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf
- -40 to 70C operating temperature range
- Complies with IEC 62443-4-2:2019 Expected to be ready by the end of Q2, 2023.
|
|
|
TN-4908-ETBN-4GTX-4GTXBP-WV-CT-T_DESCRIPTION.html
The ToughNet TN-4900 Series, designed for rolling stock
Ethernet networks, is a set of high-performance M12 routers with 8
Gigabit ports and up to four bypass relay ports. These routers feature
firewall, ETBN, and routing functionality to facilitate the deployment
of applications across networks. The TN-4900 Series routers use M12
and other circular connectors to ensure tight, robust connections
that guarantee reliability against environmental disturbances, such
as vibration and shock.
TN-4908-ETBN-4GTX-4GTXBP-WV-CT-T.html
Ethernet Interface -
10/100/1000BaseT(X) Ports (M12 X-coded 8-pin female connector) -
10/100/1000BaseT(X) Ports (M12 X-coded 8-pin female connector with bypass relay) -
Standards - IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.3af/at for PoE/PoE+ output IEEE 802.3ab for 1000BaseT(X) IEEE 802.1X for authentication IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.3x for flow control IEEE 802.3u for 100BaseT(X) IEEE 802.1p for Class of Service IEEE 802.3 for 10BaseT Ethernet Software Features -
Configuration Options - Command Line Interface (CLI) through Serial/Telnet/SSH
Web Console (HTTP/HTTPS) Windows Utility -
Filter - IGMP v1/v2
Static Multicast 802.1Q -
Management - Back Pressure Flow Control
SNMP Inform LLDP Syslog HTTP Flow control SMTP QoS/CoS/ToS Port Mirror SNMP Trap SNMPv1/v2c/v3 IPv4 Telnet DHCP server TFTP RARP Account Management -
Redundancy Protocols - RSTP
Static Port Trunk Turbo Ring v2 STP -
Routing Redundancy -
Security - Port Lock
SSH Broadcast storm protection TACACS+ Local Account Accessibility HTTPS/SSL -
Time Management -
Unicast Routing - RIPV1/V2
OSPF Static Route -
Multicast Routing DoS and DDoS Protection -
Technology - NMAP-ID Scan
ARP-Flood SYN/FIN Scan Null Scan ICMP-Death FIN Scan SYN-Flood NEWWithout-SYN Scan Xmas Scan NMAP-Xmas Scan SYN/RST Scan Firewall -
Filter - ICMP
MAC address Ethernet protocols Ports IP address DDoS -
Quick Automation Profiles - Telnet
HTTP RADIUS PROFINET EtherCAT IPsec SSH PPTP IEC 60870-104 FOUNDATION Fieldbus L2TP EtherNet/IP LonWorks DNP Modbus TCP FTP -
Stateful Inspection - Router firewall
Transparent (bridge) firewall -
Throughput - Max. 500,000 packets per second
Switch Properties -
IGMP Groups -
MAC Table Size -
Max. No. of VLANs -
VLAN ID Range LED Interface -
LED Indicators - STATE, PWR1, PWR2, FAULT, 10/100/1000M, PoE
NAT -
Features - 1-to-1
Port forwarding N-to-1 Serial Interface -
Console Port - RS-232 (M12 B-coded 5-pin female connector)
USB Interface -
M12 Connector - M12 A-coded 5-pin female (for ABC-02 USB storage)
Power Parameters -
Input Current -
Input Voltage - 24/36/48/72/96/110 VDC
Redundant dual inputs No. of power inputs: 2 -
Operating Voltage -
Overload Current Protection -
Power Connector - M12 K-coded 5-pin male connector
-
Reverse Polarity Protection Physical Characteristics -
Housing -
Dimensions - 160 x 115 x 70 mm (6.30 x 4.53 x 2.76 in)
-
IP Rating -
Weight -
Installation -
Protection - Optional PCB conformal coating
Environmental Limits -
Operating Temperature -
Storage Temperature (package included) -
Ambient Relative Humidity - 5 to 95% (non-condensing)
Standards and Certifications -
EMC -
EMS - IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF -
Freefall -
Radio Frequency -
Railway - EN 50121-4
EN 50155 IEC 60571 -
Railway Fire Protection -
Safety -
Shock - IEC 60068-2-27, IEC 61373, EN 50155
-
Vibration - IEC 60068-2-64, IEC 61373, EN 50155
Declaration MTBF
|
|