Moxa TN-5305A-WV-CT-T - EN 50155 unmanaged Ethernet switch with 5 10/100BaseT(X) ports, M12 connector, single power input by MOXA
|
|
|
|
TN-5305A-WV-CT-T_SUMMARY.html
- Rugged die-cast design for use in harsh environments
- Isolated power input range from 24 to 110 VDC
- Supports regular and push-pull M12 connectors
- Complies with all EN 50155 mandatory test itemsThis product is
suitable for rolling stock railway applications,as defined by the EN 50155 standard.For a more
detailed statement,click here:www.moxa.com/doc/specs/EN_50155_Compliance.pdf
- -40
to 70C wide-temperature design
|
|
|
TN-5305A-WV-CT-T_DESCRIPTION.html
TN-5305A-WV-CT-T - The ToughNet TN-5300A Series M12 unmanaged Ethernet switches are designed for industrial applications in harsh environments. The TN-5300A Series switches use M12 connectors to ensure tight, robust connections, and guarantee reliable resistance against environmental disturbances, such as vibration and shock. The TN-5300A Series Ethernet switches provide 5 or 8 Fast Ethernet M12 ports, support IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, MDI/MDI-X auto-sensing, and provide an economical solution for your industrial Ethernet network.
TN-5305A-WV-CT-T.html
| Switch Properties |
| Packet Buffer Size |
|
| MAC Table Size |
|
| Power Parameters |
| Input Current |
|
| Input Voltage |
|
| Total PoE Power Budget |
|
| No. of Power Inputs |
|
| Operating Voltage |
|
| Power Connector |
- M12 A-coded male connector
|
| Overload Current Protection |
|
| Reverse Polarity Protection |
|
| Environmental Limits |
| Operating Temperature |
|
| Storage Temperature (package included) |
|
| Ambient Relative Humidity |
- 5 to 95% (non-condensing)
|
| Altitude |
|
| Standards and Certifications |
| EMC |
|
| EMI |
- CISPR 32, FCC Part 15B Class A
|
| EMS |
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2
kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
|
| Radio Frequency |
|
| Environmental Testing |
- IEC 60068-2-1, EN 50155
IEC 60068-2-14, EN 50155 IEC 60068-2-2, EN 50155 IEC
60068-2-30, EN 50155 IEC 60068-2-78
|
| Railway |
- EN 50121-4
EN 50155 IEC 60571
|
| Railway Fire Protection |
|
| Safety |
- IEC 62368-1
UL 62368-1 EN 62368-1
|
| Salt Spray Test |
|
| Shock |
- IEC 60068-2-27, IEC 61373, EN 50155
|
| Vibration |
- IEC 60068-2-64, IEC 61373, EN 50155
|
| Package Vibration Test |
|
| Package Drop Test |
|
|
|
|
|