Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
Moxa TN-5816BP-LV-MV - Layer 3 Managed Ethernet switch with 16 10/100BaseT(X) ports and M12 connectors, LV-MV power Input, Relay by MOXA

Moxa TN-5816BP-LV-MV - Layer 3 Managed Ethernet switch with 16 10/100BaseT(X) ports and M12 connectors, LV-MV power Input, Relay
by MOXA

Write a review Write a review
  • Layer 3 switching functionality to divide a large network into hierarchical subnets and allow data and information to communicate across networks
  • IPv6 Ready logo awarded (IPv6 Logo Committee certified) 
  • Leading EN50155-compliant L3 Ethernet switches for rolling stock applications
  • DHCP Option 82 for IP address assignment with different policies
  • EtherNet/IP* and Modbus/TCP industrial Ethernet protocol supported
  • Turbo Ring, Turbo Chain, RSTP/STP, and MSTP* for network redundancy
  • IGMP snooping and GMRP for filtering multicast traffic
  • Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning
  • QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism
  • IEEE 802.3ad, LACP for optimum bandwidth utilization
  • SNMPv3, IEEE 802.1X, HTTPS, and SSH to enhance network security
  • SNMPv1/v2c/v3 for different levels of network management
  • RMON for efficient network monitoring and proactive capability
  • Bandwidth management prevents unpredictable network status
  • Lock port allows access by only authorized MAC addresses
  • Port mirroring for online debugging
  • Automatic warning by exception through email, relay output
  • Line-swap fast recovery
  • Automatic recovery of connected device’s IP addresses
  • LLDP for automatic topology discovery in network management software
  • Configurable by web browser, Telnet/serial console, and CLI* Windows utility
  • Panel mounting or DIN-Rail mounting installation capability
  • The ToughNet TN-5816/5818 switches are high performance M12 Layer 3 Ethernet switches that support Layer 3 routing functionality to facilitate the deployment of applications across networks. TN-5816/5818 switches use M12 and other circular connectors to ensure tight, robust connections and guarantee reliable reslience against
    environmental disturbances, such as vibration and shock. TN-5816/5818 switches provide a wide power input range of 12/24/36/48 VDC, 72/96/110 VDC, or 110/220 VDC/VAC. Dual, isolated redundant power supply increases the reliability of your communications system and saves on cabling/wiring costs. TN-5816/5818 switches provide up to 16 Fast Ethernet M12 ports with 2 bypass relay ports, and an optional 2 Ethernet interface Gigabit ports with bypass relay functionality. Models with an extended operating temperature range of -40 to 75°C are also available. TN- 5816/5818 series Ethernet switches are compliant with EN50155/50121-4 requirements, making the switches suitable for a variety of industrial applications.

    .

     Technology
    Standards IEEE 802.3 for 10BaseT
    IEEE 802.3u for 100BaseT(X)
    IEEE 802.3ab for 1000BaseT(X)
    IEEE 802.3x for Flow Control
    IEEE 802.1D for Spanning Tree Protocol
    IEEE 802.1w for Rapid STP
    IEEE 802.1Q for VLAN Tagging
    IEEE 802.1p for Class of Service
    IEEE 802.1X for Authentication
    IEEE 802.3ad for Port Trunk with LACP
    Protocols IGMPv1/v2, GMRP, GVRP, SNMPv1/v2C/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telent, SSH, Syslog, LLDP, IEEE 1588 PTP, NTP Server/Client
    MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
    Flow Control IEEE802.3x flow control, back pressure flow control
    Layer 3 Switching Static routing, RIP V1/V2, OSPF, VRRP for routing redundancy
     Switch Properties
    Priority Queues 4
    Max. Number of Available VLANs 64
    VLAN ID Range VID 1 to 4094
    IGMP Groups 256
     Interface
    Fast Ethernet Front cabling, M12 connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
    Gigabit Ethernet Down cabling, M12 connectors, 10/100/1000BaseT(X) auto negotiation speed, F/H duplex mode, auto MDI/MDI-X connection, with bypass relay function
    Console Port M12 A-coding 5-pin male connector
    System LED Indicators PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL
    Port LED Indicators 10/100M (Fast Ethernet port), 10/100/1000M (Gigabit Ethernet port)
    Alarm Contact 2 relay outputs in one M12 A-coding 5-pin male connector with current carrying capacity of 3 A @ 30 VDC
    Rotary Switches For setting the last 3 digits of the IP address
     Power Requirements
    Input Voltage • LV: 12/24/36/48 VDC (8.4 to 60 VDC)
    • MV: 72/96/110 VDC (50.4 to 154 VDC)
    • HV: 110/220 VDC/VAC (88 to 300 VDC, 85 to 264 VAC)
    Input Current • TN-5816BP Series:
    0.793 A @ 24 VDC, 0.302 A @ 72 VDC,
    0.203 A @ 110 VDC, 0.465 A @ 110 VAC 
    0.286 A @ 220 VAC
    • TN-5818 Series:
    1.016 A @ 24 VDC, 0.39 A @ 72 VDC,
    0.253 A @ 110 VDC, 0.569 A @ 110 VAC,
    0.338 A @ 220VAC
    Overload Current Protection Present
    Connection M23 connector
    Reverse Polarity Protection Present
     Physical Characteristics
    Housing Metal, IP54 protection (optional protective caps available for unused ports)
    Dimensions TN-5816BP Series: 250 x 175.8 x 115 mm (9.84 x 6.92 x 4.53 in)
    TN-5818 Series: 250 x 181.4 x 115 mm (9.84 x 7.14 x 4.53 in)
    Weight TN-5816 Series: 2900 g
    TN-5818 Series: 3002 g
    Installation Panel mounting, DIN-Rail mounting (with optional kit: DK-DC50131)
     Environmental Limits
    Operating Temperature Standard Models: -25 to 60°C (-13 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)
    Storage Temperature -40 to 85°C (-40 to 185°F)
    Ambient Relative Humidity 5 to 95% (non-condensing)
    Altitude Up to 2000 m
    Note Please contact Moxa if you require products guaranteed to function at higher altitudes
     Standards and Certifications
    Safety UL 508 (Pending)
    EMI FCC Part 15 Subpart B Class A, EN 55022 Class A
    EMS EN 61000-4-2 (ESD) Level 3
    EN 61000-4-3 (RS) exceeds Level 3
    EN 61000-4-4 (EFT) Level 3
    EN 61000-4-5 (Surge) Level 3
    EN 61000-4-6 (CS) Level 3
    EN 61000-4-8
    EN 61000-4-11
    Rail Traffic (for panel mounting installations)
    EN 50155*, EN 50121-4
    Note *Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details.
    Shock IEC 61373
    Freefall IEC 60068-2-32
    Vibration IEC 61373
    Note Please check Moxa’s website for the most up-to-date certification status.