- Communicates with HMI/SCADA software via Modbus/TCP
- Integrated with iView2 - SNMP Management Software (free download)
- Energy Efficient Ethernet (EEE), IEEE 802.3az for low energy consumption
- Wide temperature range -40 to 75°C
- DIN rail or wall/panel mountable
- Redundant dual 12 to 48VDC power inputs
- EMS Level 3 Protection
- Designed for hazardous locations: UL C1D2, ATEX Zone 2 (pending), IECEx (pending)
- Port-based QoS feature for deterministic data transmission
- Loop detection and event alarm
- Power failure indicated by a relay and LED indicator
|
|
|
SE300 series is the industry’s first design for Ethernet Green® , IEEE802.3az - Energy Ethernet switches that cut power usage by up to 60%, significantly saving energy usage in the field and reducing total cost of ownership over 24/7.
Advantech B+B SmartWorx SE300 series monitored switches can be used as plug-andplay unmanaged switches right out of the box. Installing the iView² Network Management Software gives them basic monitoring and management capabilities as well. They bridge the gap between unmanaged switches and significantly more expensive, fully managed solutions.
When enabled with iView2 , these switches provide IP address assignment, allowing for a static IP address or an address that is discoverable via DHCP in the network. Then, these switches have the ability to use Modbus/TCP to communicate with HMI/SCADA software and SNMP to communicate with NMS (Networking Management Software) at the same time. This gives full access control to both control engineers and IT managers.
Basic Monitoring & Management Capabilities
iView2 gives network managers the ability to monitor and manage eWorx SE300 series switches from a central location. It features an intuitive Graphical User Interface (GUI) that provides a real-life representation of all installed eWorx SE300 Series switches, displaying device functions, port settings, device status information and traffic statistics via SNMP.
iView2 can also configure eWorx SE300 series switches monitoring capabilities for automation applications via the popular Modbus TCP/IP protocol. Control engineers can use existing HMI/SCADA software to integrate the network status by creating extra tags for real-time monitoring. iView2 is a standalone software that supports multiple platforms and operating systems.
iView2 Features for eWorx SE300 series Switches
Monitoring:
- System information (IP/MAC address)
- Port status
- Port speed
- Flow control
- Link up counter
- TX packets counter, RX packets counter
- TX error packets counter, RX error packets counter
- Firmware version
- PoE status (PoE model/s only)
Management:
- Configure IP mode
- Set IP address
- Set TCP Modbus/TCP time-out
- Create Community Strings
- Configure Traps
COMMUNICATIONS |
Standards |
IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, 802.1p, 802.3az |
LAN |
10/100/1000Base-T(X) |
Transmission Distance |
100 m |
Transmission Speed |
Up to 1000Mbps |
INTERFACE |
Connectors |
SEG305-T: 5 x RJ45 SEG308-T: 8 x RJ45 6-pin removable screw terminal (power & relay) |
Ethernet |
Auto Sensing, 10/100/1000BaseTX, Duplex and MDIX |
LED Indicators |
P1, P2, P-Fail, Loop Detection 10/100/1000T(X): Link/Activity, Speed |
SWITCH PROPERTIES |
MAC Table Size |
SEG305-T: 2k
SEG308-T: 8k |
Packet Buffer Size |
SEG305-T: 1M bit
SEG308-T: 4.1M bit |
Switching Capacity |
SEG305-T: 10 Gbps
SEG308-T: 16 Gbps |
Jumbo Frame |
9216 bytes |
POWER |
Power Consumption |
SEG305-T: Max. 2W. SEG308-T: Max. 5.2W |
Power Input |
12~48 VDC (8.4~52.8 VDC) redundant dual inputs |
Fault Output |
1 Relay Output |
Reverse Polarity Protection |
Present |
Overload Current |
Present |
PHYSICAL |
Dimensions (WxHxD) |
SEG305-T: 27 x 120 x 84 mm. SEG308-T: 43 x 120 x 84 mm |
Enclosure |
IP30, metal shell with solid mounting kits |
Mounting |
DIN-Rail, Wall |
ENVIRONMENT |
Operating Temperature |
-40 ~ 75°C (-40 ~ 167°F) |
Storage Temperature |
-40 ~ 85°C (-40 ~ 185°F) |
Operating Humidity |
10 ~ 95% (non-condensing) |
Storage Humidity |
10 ~ 95% (non-condensing) |
MTBF |
SEG305-T: 5,168,110 hours
SEG308-T: 4,176,861 hours |
CERTIFICATIONS |
Hazardous Environments |
UL Class 1 Division 2 Groups A,B,C,D; ATEX Zone 2 (pending); IECEx (pending) |
Safety |
UL508 |
EMI |
FCC Part 15 Subpart B Class A, EN 55011/55022, Class A |
EMS |
EN 61000-4-2 (Level 3), EN 61000-4-3 (Level 3)
EN 61000-4-4 (Level 3), EN 61000-4-5 (Level 3)
EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 3) |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6 |
SOFTWARE |
Management |
iView2 , LLDP, SNMP v1/v2c, Modbus/TCP |
Configuration |
Static IP address, DHCP Client |
Monitoring |
Port Statistics (Speed/Status), Link Up/Down counter, Error Packet counter, Loop detection |
Filter |
Flow control, IEEE 802.1p QoS(Strict mode), Broadcast storm protection |
Industrial Profiles |
Modbus/TCP profiles included - Configuration and Diagnostic via automation software tools like e.g. Wonderware InTouch, STEP7, InduSoft Web Studio |
IVIEW2 - NETWORK MANAGEMENT SOFTWARE - FREE DOWNLOAD |
Version |
iView2 Web-based Application |
OS Support |
32-bit/64-bit Windows XP/Vista/7, Windows Server 2003/2008/2008 R2 |
Operation Modes |
Local Computer or Remote Server |
Web Browser |
Microsoft® IE, Chrome, Firefox |
Protocol |