Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
SEG316-T - *Discontinued* - ESW, SNMP, MODBUS, (16)10/100, (2) GIG OR SFP, WT by Advantech/ B+B Smartworx

SEG316-T - *Discontinued* - ESW, SNMP, MODBUS, (16)10/100, (2) GIG OR SFP, WT
by Advantech/ B+B Smartworx

Write a review Write a review
  • Communicates with HMI/SCADA software via Modbus/TCP
  • Integrated with iView2 - SNMP Management Software (free download)
  • Energy Efficient Ethernet (EEE), IEEE 802.3az for low energy consumption
  • Wide temperature range -40 to 75°C
  • DIN rail or wall/panel mountable
  • Redundant dual 12 to 48VDC power inputs
  • EMS Level 3 Protection
  • Designed for hazardous locations: UL C1D2, ATEX Zone 2 (pending), IECEx (pending)
  • Port-based QoS feature for deterministic data transmission
  • Loop detection and event alarm
  • Power failure indicated by a relay and LED indicator

 

SE300 series is the industry’s first design for Ethernet Green® , IEEE802.3az - Energy Ethernet switches that cut power usage by up to 60%, significantly saving energy usage in the field and reducing total cost of ownership over 24/7.

Advantech B+B SmartWorx SE300 series monitored switches can be used as plug-andplay unmanaged switches right out of the box. Installing the iView² Network Management Software gives them basic monitoring and management capabilities as well. They bridge the gap between unmanaged switches and significantly more expensive, fully managed solutions.

When enabled with iView2 , these switches provide IP address assignment, allowing for a static IP address or an address that is discoverable via DHCP in the network. Then, these switches have the ability to use Modbus/TCP to communicate with HMI/SCADA software and SNMP to communicate with NMS (Networking Management Software) at the same time. This gives full access control to both control engineers and IT managers.

Basic Monitoring & Management Capabilities

iView2 gives network managers the ability to monitor and manage eWorx SE300 series switches from a central location. It features an intuitive Graphical User Interface (GUI) that provides a real-life representation of all installed eWorx SE300 Series switches, displaying device functions, port settings, device status information and traffic statistics via SNMP.

iView2 can also configure eWorx SE300 series switches monitoring capabilities for automation applications via the popular Modbus TCP/IP protocol. Control engineers can use existing HMI/SCADA software to integrate the network status by creating extra tags for real-time monitoring. iView2 is a standalone software that supports multiple platforms and operating systems.

iView2 Features for eWorx SE300 series Switches

Monitoring:

  • System information (IP/MAC address)
  • Port status
  • Port speed
  • Flow control
  • Link up counter
  • TX packets counter, RX packets counter
  • TX error packets counter, RX error packets counter
  • Firmware version
  • PoE status (PoE model/s only)

Management:

  • Configure IP mode
  • Set IP address
  • Set TCP Modbus/TCP time-out
  • Create Community Strings
  • Configure Traps

COMMUNICATIONS

Standards

IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, 802.1p, 802.3az

LAN

10/100/1000Base-T(X)

Transmission Distance

Up to 100 meters

Transmission Speed

100Mbps

INTERFACE

Connectors

16 x RJ45

6-pin removable screw terminal (power & relay)

Ethernet

Auto Sensing, 10/100/1000BaseTX, Duplex and MDIX

LED Indicators

P1, P2, P-Fail, Loop Detection 10/100T (X): Link/Activity, Speed

SWITCH PROPERTIES

MAC Table Size

8k

Packet Buffer Size

4.1M bit

Switching Capacity

32 Gbps

Jumbo Frame

9126 bytes

POWER

Power Consumption

Max. 8W

Power Input

12 - 48 VDC (8.4-52.8 VDC) redundant dual inputs

Fault Output

1 Relay Output

Reverse Polarity Protection

Present

Overload Current

Present

PHYSICAL

Dimensions (WxHxD)

74 x 120 x 84 mm

Enclosure

IP30, metal shell with solid mounting kits

Mounting

DIN-Rail, Wall

ENVIRONMENT

Operating Temperature

-40 - 75°C (-40 - 167°F)

Storage Temperature

-40 - 85°C (-40 - 185°F)

Operating Humidity

10 - 95% (non-condensing)

Storage Humidity

10 - 95% (non-condensing)

MTBF

4,653,552 hours

CERTIFICATIONS

Hazardous Environments

UL Class 1 Division 2 Groups A,B,C,D; ATEX Zone 2 (pending); IECEx (pending)

Safety

UL508

EMI

FCC Part 15 Subpart B Class A, EN 55011/55022, Class A

EMS

EN 61000-4-2 (Level 3), EN 61000-4-3 (Level 3)

EN 61000-4-4 (Level 3), EN 61000-4-5 (Level 3)

EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 3)

Shock

IEC 60068-2-27

Freefall

IEC 60068-2-32

Vibration

IEC 60068-2-6

SOFTWARE

Management

iView2 , LLDP, SNMP v1/v2c, Modbus/TCP

Configuration

Static IP address, DHCP Client

Monitoring

Port Statistics (Speed/Status), Link Up/Down counter, Error Packet counter, Loop detection

Filter

Flow control, IEEE 802.1p QoS(Strict mode), Broadcast storm protection

Industrial Profiles

Modbus/TCP profiles included - Configuration and Diagnostic via automation software tools like e.g. Wonderware InTouch, STEP7, InduSoft Web Studio

IVIEW2 - NETWORK MANAGEMENT SOFTWARE - FREE DOWNLOAD

Version

iView2 Web-based Application

OS Support

32-bit/64-bit Windows XP/Vista/7, Windows Server 2003/2008/2008 R2

Operation Modes

Local Computer or Remote Server

Web Browser

Microsoft® IE, Chrome, Firefox

Protocol

SNMPv1 and SNMPv2c

 

 


Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.