Power |
Dual
Power
Input |
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
12/24/48 VDC Nominal. ( 9.6 to 60 VDC)
18 to 30 VAC |
Power |
4-Pin Removable Terminal Block. |
Connector |
Grounding screw on metal chassis |
Maximum Current Consumption
@24 vDC |
140 mA |
Maximum Power
Consumption
@24 vDC |
3.4 Watts |
Overload
Current
Protection |
Reset-able fuse provides overload current protection |
Reverse
polarity
protection |
The positive and negative inputs can be reversed providing safe and simple power connectivity. |
Access Ports |
RJ45 |
4 or 5 shielded RJ45 ports for 10/100Base-TX up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
Ethernet isolation 1500 V |
Fiber port |
1 x fixed fiber port
Duplex SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
Simplex ( BIDI, single strand ) SC connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
PC and UPC type patch cords supported. |
Fixed
Fiber
Port
Specs |
Fiber1
Type |
Transmit
(dBm) |
Receive
(dBm) |
Power
Budget
(dB) |
Wavelength
(nm) |
IEEE |
Core
Size
(um) |
Modal
Bandwidth
(MHz
*Km) |
Maximum
Operating
Distance |
Min |
Max |
Min |
Max |
MMF
(Duplex
SC/ST) |
-20.0 |
-12.0 |
-31.0 |
-14.0 |
11.0 |
1310 |
100Base-FX |
50 |
800* |
5 Km
3.1 mi |
62.5 |
500* |
4 Km
2.5 mi |
62.5 |
200 |
2 Km
1.2 mi |
MMF
(Simplex
SC/ST) |
-15.0 |
0.0 |
-28.0 |
-8.0 |
13.0 |
1310 / 1550
1550 / 1310 |
100Base-BX-U
100Base-BX-D |
62.5 |
200 |
2 Km
1.2 mi |
SMF
(Duplex
SC/ST) |
-18.0 |
-7.0 |
-32.0 |
-3.0 |
14.0 |
1310 |
100Base-LX |
9 |
** |
20 Km
12.4 mi |
SMF
(Simplex
SC) |
-14.0 |
-8.0 |
-32.0 |
-3.0 |
18.0 |
1310 / 1550
1550 / 1310 |
100Base-BX-U
100Base-BX-D |
9 |
** |
20 Km
12.4 mi |
SMF
(Duplex
SC/ST) |
-5.0 |
0.0 |
-34.0 |
-3.0 |
29.0 |
1310 |
100Base-EX |
9 |
** |
40 Km
24.9 mi |
SMF
(Simplex
SC) |
-8.0 |
-3.0 |
-33.0 |
-3.0 |
18.0 |
1310 / 1550
1550 / 1310 |
100Base-BX-U
100Base-BX-D |
9 |
** |
40 Km
24.9 mi |
SMF
(Duplex
SC/ST) |
-5.0 |
0.0 |
-34.0 |
-3.0 |
29.0 |
1550 |
100Base-ZX |
9 |
** |
80 Km
4.79 mi |
SMF
(Duplex
SC/ST) |
0.0 |
5.0 |
-35.0 |
-3.0 |
35.0 |
1550 |
100Base-ZX |
9 |
** |
120 Km
74.6 mi |
* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications |
Switch Properties |
Standards |
- IEEE 802.3 for 10Base-T
- IEEE 802.3u for 100Base-TX and 100Base-FX
- IEEE 802.3x for Flow Control
|
Processing Type |
Store and Forward, non-blocking architecture |
MAC Address Table Size |
1024 |
Packet Buffer Memory |
512 Kbit |
Indicators |
P1 |
This green LED is turned on when power is applied to the power #1 input |
P2 |
This green LED is turned on when power is applied to the power #2 input |
RJ45 Ethernet |
These integrated colored LEDs indicate link, activity and speed for each port. |
Fiber Link |
Fiber link LED indicates Link and Data Activity |
Environmental Specifications |
Operating Temperature Ranges |
Standard temperature models : 0° C to 60° C (32° F to 140° F).
Industrial extended temperature models : -40° C to 75° C ( -40 F to 167° F ) |
Storage Temperature Range |
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models |
Operating Humidity Range |
5% to 90% non-condensing |
Storage Humidity Range |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Chassis |
Aluminum with an IP30 ingress protection rating |
Din Rail Mountable |
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit |
Maximum Heat Output |
11.6 BTU/Hr |
MTBF |
913,428 hours (without fiber module)
717,100 hours (with fiber module)
MTBF Calculation model based on MIL-HDBK-217-FN2 @ 30 °C |
Product Weight and Dimensions |
Weight |
0.19 kg, 0.3 lbs |
Dimensions |
30 x 115 x 70 mm, 1.18 x 4.52 x 2.76 inches |
Packaging |
Shipping Weight |
0.34 kg, 0.8 lbs |
Shipping Dimensions |
170 x 260 x 70 mm, 6.69 x 10.24 x 2.76 inches |
Contents Shipped |
Industrial Ethernet Switch with DIN Rail attachment
Terminal block
Installation guide |
Standards and Certifications |
Safety |
UL 60950-1
CSA C22.2 No. 60950-1
IEC 60950-1:2005+A1:2009 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
CE Mark
UL508 ( Industrial ) |
EMC Emissions |
FCC 47 Part 15 Class B
ICES-0003
CISPR 22:2008/EN55022:2010 (Class B)
EN61000-6-4 |
EMC Immunity |
CISPR 24:2010/EN 55024:2010
IEC/EN 61000-4-2 (ESD) : Contact discharge +/- 6kV, Air Discharge +/- 8kV
IEC/EN 61000-4-3 (RS) : 80 MHz to 2.7 Ghz ; 10V/m, 800 MHz to 1000 MHz; 20V/m
IEC/EN 61000-4-4 (EFT) : DC power line +/- 2 kV, Data Line +/- 2kV
IEC/EN 61000-4-5 (Surge) : DC power line, Line/Line +/- 1kV, Line/Earth +/- 2kV, Data Line line/earth +/- 1kV
IEC/EN 61000-4-6 (CS) : 150kHz to 80 MHz; 10V
IEC/EN 61000-4-8 (Magnetic Field): 30 A/m
IEC/EN 61000-6-2 ( General Immunity in Industrial Environments ) |
Industrial Safety |
UL508 (Safety standard for Industrial Control Equipment )
CSA C22.2 No. 142 |
Hazardous Locations
( Hazloc ) |
ANSI/ISA 12.12.01, Class I Division 2 Groups A-D ( formerly known as UL 1604 )
CSA C22.2 No. 213
ATEX Class I Zone 2, EN60079-0,15 |
Laser Safety |
EN 60825-1:2007
Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11. |
Environmental |
Reach, RoHS and WEEE Compliant |
Other |
ECCN: 5A991 |
HTSUS Number: 8517.62.0050 |
|