						Moxa EDS-205A-M-SC-T-IEX-Unmanaged switch with 4 10/100BaseT(X) ports, and 1 100BaseFX multi-mode port with SC connector,-40 to by  MOXA
					 | 
														 
				 |  
								
					| 
						
					 | 
				 
					 
		
  - Ethernet: 10/100BaseT(X) (RJ45 connector),
 
  - Fiber: 1 x 100BaseFX (multi-mode, SC connector)
 
  - Redundant dual 12/24/48 VDC, 18 to 30 VAC power inputs
 
  - IP30 aluminum housing
 
  - Rugged hardware design well suited for hazardous locations (Class 1 Div. 2/ATEX Zone 2), Transportation (NEMA TS2/ EN 50121-4/e-Mark), and maritime environments (DNV/GL/LR/ABS/NK)
 
  - -40 to 75°C (-40-167°F) operating temperature range
 
 
         | 
       
       |  
     
     | 
   
  
    
	
		
		
The EDS-205A-M-SC-T-IEX series are 5-port industrial Ethernet switches that support IEEE 802.3 and IEEE 802.3u/x with 10/100M full/half-duplex, MDI/MDI-X auto-sensing. The EDS-205A-M-SC-T-IEX switches provide 12/24/48 VDC (9.6 to 60 VDC), 18 to 30 VAC redundant power inputs that can be connected simultaneously to live AC/DC power sources. These switches have been designed for harsh industrial environments, such as in maritime (DNV/GL/LR/ABS/NK), rail wayside, highway, or mobile applications(EN 50121-4/NEMA TS2/e-Mark), or hazardous locations (Class I Div. 2, ATEX Zone 2) that comply with FCC, UL, and CE standards. 
The EDS-205A-M-SC-T-IEX switches are available with a wide operating temperature range from -40 to 75°C. All models are subjected to a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. In addition, the  
  EDS-205A-M-SC-T-IEX switches have DIP switches for enabling or disabling broadcast storm protection, providing another level of flexibility for industrial applications. 
  
 
		
  
    
      | • Technology | 
     
    
      | Standards | 
      IEEE 802.3 for 10BaseT 
        IEEE 802.3u for 100BaseT(X) and 100BaseFX 
        IEEE 802.3x for Flow Control | 
     
    
      | Processing Type | 
      Store and Forward | 
     
    
      | Flow Control | 
      IEEE 802.3x flow control, back pressure flow control | 
     
    
      | • Switch Properties | 
     
    
      | MAC Table Size | 
      1 K | 
     
    
      | Packet Buffer Size | 
      512 kbit | 
     
    
      | • Interface | 
     
    
      | Fiber Ports | 
      100BaseFX ports (SC/ST connector, multi-mode, single-mode) | 
     
    
      | RJ45 Ports | 
      10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection | 
     
    
      | DIP Switches | 
      Enable/Disable broadcast storm protection | 
     
    
      | LED Indicators | 
      Power, 10/100M (TP port), 100M (fiber port) | 
     
    
      | • Optical Fiber | 
     
    
      
        | 
     
    
      | • Power Requirements | 
     
    
      | Input Voltage | 
      12/24/48 VDC (9.6 to 60 VDC), 18 to 30 VAC (47 to 63 Hz), redundant dual inputs | 
     
    
      | Input Current | 
      EDS-205A: 0.1 A @ 24 V 
        EDS-205A-M/S: 0.11 A @ 24 V 
        EDS-208A: 0.13 A @ 24 V 
        EDS-208A-M: 0.17 A @ 24 V 
        EDS-208A-MM/SS: 0.22 A @ 24 V | 
     
    
      | Overload Current Protection | 
      1.1 A | 
     
    
      | Connection | 
      1 removable 4-contact terminal block | 
     
    
      | Reverse Polarity Protection | 
      Present | 
     
    
      | • Physical Characteristics | 
     
    
      | Housing | 
      Aluminum, IP30 protection | 
     
    
      | Dimensions | 
      EDS-205A Series: 30 x 115 x 70 mm (1.18 x 4.52 x 2.76 in) 
        EDS-208A Series: 50 x 115 x 70 mm (1.96 x 4.52 x 2.76 in) | 
     
    
      | Weight | 
      EDS-205A Series: 175 g 
        EDS-208A Series: 275 g | 
     
    
      | Installation | 
      DIN-rail mounting, wall mounting (with optional kit) | 
     
    
      | • Environmental Limits | 
     
    
      | Operating Temperature | 
      Standard Models: -10 to 60°C (14 to 140°F) 
        Wide Temp. Models: -40 to 75°C (-40 to 167°F) | 
     
    
      | Storage Temperature | 
      -40 to 85°C (-40 to 185°F) | 
     
    
      | Ambient Relative Humidity | 
      5 to 95% (non-condensing) | 
     
    
      | • Standards and Certifications | 
     
    
      | Safety | 
      UL 508 | 
     
    
      | Hazardous Location | 
      UL/cUL Class 1 Division 2 Groups A/B/C/D,  
        ATEX Zone 2 Ex nA nC IIC T4 Gc, , IECEx* (EDS-205A series, -IEX models only) | 
     
    
      | EMI | 
      FCC Part 15 Subpart B Class A, EN 55022 Class A | 
     
    
      | EMS | 
      EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, 
        EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, 
        EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-11 | 
     
    
      | Marine | 
      DNV, GL, LR, ABS, NK | 
     
    
      | Wheeled Vehicles | 
      e-Mark (E1) (EDS-208A only) | 
     
    
      | Traffic Control | 
      NEMA TS2 | 
     
    
      | Rail Traffic | 
      EN 50121-4 | 
     
    
      | Shock | 
      IEC 60068-2-27 | 
     
    
      | Freefall | 
      IEC 60068-2-32 | 
     
    
      | Vibration | 
      IEC 60068-2-6 | 
     
    
      | • MTBF (mean time between failures) | 
     
    
      | Time | 
      EDS-205A Series: 3,040,784 hrs 
        EDS-208A Series: 2,428,212 hrs | 
     
    
      | Database | 
      Telcordia (Bellcore), GB | 
     
  
 
		 
		
	 
 
		 | 
   
  
     | 
   
  
     | 
   
 
 
											 |