Physical Ports |
|
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX |
8 |
Technology |
|
Ethernet Standards |
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow control |
MAC Table |
8192 MAC addresses |
Processing |
Store-and-Forward |
LED Indicators |
|
Power Indicator |
Green : Power LED x 3 |
Fault Indicator |
Amber : Indicates PWR1 or PWR2 failure occurred |
10/100/1000Base-T(X) / Fiber Port Indicator |
Green for port Link/Act. Amber for 100Mbps indicator |
10/100Base-T(X) RJ45 Port Indicator |
Green for port Link/Act. Amber for Duplex/Collision |
Power |
|
Redundant Input Power |
Triple DC inputs. 12~48VDC on 7-pin terminal block, 12~45VDC on power jack |
Power Consumption (Typ.) |
4 Watts |
Overload Current Protection |
Present |
Reverse Polarity Protection |
Present |
Physical Characteristics |
|
Enclosure |
IP-30 |
Dimensions (W x D x H) |
52(W)x106.1(D)x144.3(H) mm |
Weight (g) |
666 g |
Environmental |
|
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Operating Temperature |
-40 to 70°C (-40 to 158°F) |
Operating Humidity |
5% to 95% Non-condensing |
Regulatory Approvals |
|
EMI |
FCC Part 15, CISPR (EN55022) class A |
EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
Shock |
IEC60068-2-27 |
Free Fall |
IEC60068-2-32 |
Vibration |
IEC60068-2-6 |
Safety |
EN60950, UL508 (E331061), UL/cUL Class 1 Division 2 Group A/B/C/D, ATEX Class 1 Zone 2 |