ICP DAS NSM-206AFC-T - Multi-mode, SC Connector, 4-Port 10/100 Mbps with 2 Fiber ports Switch, metal case by ICP DAS
|
|
|
|
NSM-206AFC-T_SUMMARY.html
- Provides 6 x 100-FX fi ber port plus 4 x Ethernet ports
- Each port supports both 10/100 Mbps speed auto negotiation
- Full duplex IEEE 802.3x and half duplex backpressure
flow control
- DIN-Rail
- Automatic MDI/MDI-X crossover for plug-and-play
- Store-and-forward architecture
- Redundant dual +12 ~ 48 VDC power inputs
- Supports operating temperatures from -30 ~ +75C
|
|
|
NSM-206AFC-T_DESCRIPTION.html
NSM-206AFC-T - Multi-mode, SC Connector, 4-Port 10/100 Mbps with 2 Fiber ports Switch, metal case, Supports Input Voltage Range of 12 ± 48VDC, has an FC connector, operates up to 75C
NSM-206AFC-T.html
| Models | NS-206AF | NSM-206AF | | Technology | | Standards | IEEE 802.3, 802.3u, 802.3x | | Processing Type | Store & forward; wire speed switching | | MAC Addresses | 1024 | | Memory Bandwidth | 2.0 Gbps | | Frame Buffer Memory | 512 Kbit | | Flow Control | IEEE 802.3x flow control, back pressure flow control | | Ethernet Interface | | RJ-45 Ports | 10/100 Base-T(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection | | LED Indicators | Power, Link/Act, 10/100M | | Ethernet Isolation | 1500 Vrms 1 minute | | +/- 4 kV ESD Protection | Yes | | Fiber Interface (100 Base-FX; SC/ST type) | | Multi-Mode | NS-206AFT-T/FC-T NSM-206AFT-T/FC-T | Multi mode fiber cables: 50/125, 62.5/125 or 100/140 um Distance: 2 km, (62.5/125 um recommended) for full duplex Wavelength: 1300 or 1310nm Min. TX Output: - 20 dBm Max. TX Output: - 14 dBm Max. RX Sensitivity: -32 dBm Max. RX Overload: -8 dBm Budget: 12 dBm | | Single-Mode | NS-206AFCS-T NSM-206AFCS-T | Single-mode fiber cables: 8.3/125, 8.7/125, 9/125, or 10/125um Distance: 30 Km, (9/125 um recommended) for full duplex Wavelength: 1300 or 1310nm Min. TX Output: - 15 dBm Max. TX Output - -8 dBm Max. RX Sensitivity: -34 dBm Max. RX Overload: -5 dBm Budget: 19 dBm | | Single-Mode | NS-206AFCS-60T NSM-206AFCS-60T | Single-mode fiber cables: 8.3/125, 8.7/125, 9/125 or 10/125 um Distance: 60 Km, (9/125 um recommended) for full duplex Wavelength: 1300 or 1310nm Min. TX Output: - 5 dBm Max. TX Output - 0 dBm Max. RX Sensitivity: -35 dBm Max. RX Overload: -5 dBm Budget: 30 dBm | | Power Input | | Input Voltage Range | +12 ~ +48 Vdc (Redundant input) | | Power consumption | 0.14 A@ 24 Vdc | | Protection | Power reverse polarity protection | | +/-4 kV ESD Protection | Yes | | Connection | 6-Pin Removable Terminal Block | | Mechanical | | Casing | Plastic (Flammability UL 94V-0) | Metal (IP30 Protection) | | Dimensions (W x L x H) | 31 mm x 157mm x 113mm | 25 mm x 168 mm x 119 mm | | Installation | DIN-Rail | | Environmental | | Operating Temperature | -30C ~ +75C | | Storage Temperature | -40C ~ +85C | | Ambient Relative Humidity | 10% ~ 90% RH, non-condensing |
|
|
|
|