• Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.3az for Energy-Efficient Ethernet |
Processing Type |
Store and Forward |
Flow Control |
IEEE 802.3x flow control, back pressure flow control |
• Switch Properties |
MAC Table Size |
8 K |
Packet Buffer Size |
1024 kbit |
Jumbo Frame Size |
10 KB |
• Interface |
RJ45 Ports |
10/100/1000BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection |
Fiber Ports |
100/1000BaseSFP slot (SFP model) |
DIP Switches |
One for port break alarm, one for Enable/Disable broadcast storm protection, jumbo frame, IEEE 802.3az energy saving and 100/1000 SFP speed switching |
LED Indicators |
PWR1, PWR2, FAULT, 10/100/1000M |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
• Power Requirements |
Input Voltage |
12/24/48 VDC (9.6 to 60 VDC), redundant dual inputs |
Input Current |
EDS-G205-1GTXSFP: 0.16 A @ 24 V |
Connection |
1 removable 6-contact terminal block |
Reverse Polarity Protection |
Present |
• Physical Characteristics |
Housing |
Metal, IP30 protection |
Dimensions |
EDS-G205-1GTXSFP Series: 29 x 135 x 105 mm (1.14 x 5.31 x 4.13 in) |
Weight |
EDS-G205-1GTXSFP Series: 290 g |
Installation |
DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits |
Operating Temperature |
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
Safety |
UL 508 |
Hazardous Location |
UL/cUL Class 1 Division 2 Groups A/B/C/D,
ATEX Zone 2 Ex nA nC IIC T4 Gc (Pending) |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
EMS |
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3 |
Rail Traffic |
EN-50121-4 |
Marine |
DNV, GL, LR, ABS, NK (Pending) |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6 |
Note |
Please check Moxa’s website for the most up-to-date certification status. |
• MTBF (mean time between failures) |
Time |
2,823,446 hrs |
Database |