IEC-G102-BP-Pro - Industrial Intrusion Prevention System (IPS) device with 2 10/100/1000BaseT(X) ports, 1 year of pattern update by MOXA
|
|
|
- Ultra-compact industrial security box with IPS/IDS
- Granular policy enforcement with whitelisting control
- LAN Bypass design to prevent a single point of failure and traffic overloading
- Bump-in-the-wire installation without impacting the network
|
|
|
The Moxa IEC-G102-BP-Pro Series industrial next-generation IPS devices protect mission-critical assets with industrial-grade IPS and whitelisting. Meanwhile, the Security Dashboard Console (SDC) software, when used together with the IEC-G102-BP Series, offers another layer of protection through centralized critical asset visibility, network analysis, and auto pattern updating.
Input/Output Interface
Ethernet Interface
-
10/100/1000BaseT(X) Ports (RJ45 connector)
-
Standards
- IEEE 802.3 for 10BaseT
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3u for 100BaseT(X)
LED Interface
-
LED Indicators
- PWR1, PWR2, MANAGED, IPS/IDS, USB/F, BYPASS, 10/100/1000M
DoS and DDoS Protection
-
Technology
- ICMP Flood, IGMP Flood, UDP Flood, TCP SYN Flood, TCP Port SYN Scan, TCP Port FIN Scan, TCP Port NULL Scan, TCP Port Xmas Scan, UDP Port Scan
Firewall
-
IPS Throughput
-
Latency
-
Deep Packet Inspection
- Modbus TCP
Modbus UDP
EtherNet/IP
PROFINET-DCP
CIP
SLMP
Omron FINS
Siemens S7 Comm.
Siemens S7 Comm. Plus
Additional protocols will be supported through future firmware updates.
-
Policy Enforcement Rules
-
ICS Protocol Filter Profiles
-
Concurrent Connections (TCP)
-
Automatic Pattern Updates via SDC
- Yes, 1 year of updates included
-
Manual Pattern Updates
- Yes, 1 year of updates included
Management
-
Supported Interfaces
- Web GUI
Security Dashboard Console (SDC)
Real-Time Firewall / VPN Event Log
-
Event Type
- Cybersecurity, Policy enforcement, Protocol Filter, Assets detection, System event
-
Media
- Local storage, Syslog server
Serial Interface
Power Parameters
-
Connection
-
Input Current
- 0.605 A @ 12 VDC, 0.297 A @ 24 VDC, 0.143 A @ 48 VDC
Physical Characteristics
-
Housing
-
Dimensions
- 40 x 70 x 83 mm (1.58 x 2.76 x 3.27 in)
-
Weight
-
Installation
- DIN-rail mounting, Wall mounting (with optional kit)
Environmental Limits
-
Operating Temperature
- -10 to 60°C (14 to 140°F)
-
Storage Temperature
- -40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
-
Safety
- UL 60950-1 Ed.2, UL 62368-1
-
EMC
-
EMI
- CISPR 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF
-
Hazardous Locations
- UL/cUL Class I trision 2 Groups A/B/C/D
-
Railway
-
Traffic Control
-
Shock
-
Freefall
-
Vibration
MTBF
Warranty
|
|