Advantech ADAM-6266-AE - "Discontinued" - 4-CH RELAY OUTPUT MODBUS TCP MODULE WITH 4-CH DI by Advantech
|
|
|
|
- 4-ch Relay Output, 4-ch DI, 2-port Ethernet
- Daisy chain connection with auto-bypass protection
- Remote monitoring and control with mobile devices
- Group configuration capability for multiple module setup
- Flexible user-defined Modbus address
- Intelligent control ability by Peer-to-Peer and GCL function
- Multiple protocol support: Modbus TCP, TCP/IP, UDP, HTTP, DHCP
- Web language support: XML, HTML 5, Java Script
|
|
|
ADAM-6266-AE
In order to fulfill ideal remote DAQ devices in IoT world, Advantech releases ADAM-6200 series, a new selection of Ethernet I/O family comprised of analog I/O, digital I/O and relay modules. ADAM-6200 series module possesses plenty of advanced features whatever the evolution of hardware design and what’s worth expecting for user is a variety of useful software functions to make it effective in the application field. With new design and strong capabilities, ADAM-6200 can be a well-integrated I/O solution in Ethernet control system.
| Digital Input |
| Channels |
4 |
| Counter Input |
3kHz (32 bit + 1 bit overflow) |
| Dry Contract |
Logic 0: Open, Logic 1: Closed to DI COM |
| Frequency Input Range |
0.1 ~ 3kHz |
| Input Impedance |
5.2 kW (Wet Contact) |
| Input Voltage |
Dry contact: Logic level 0: close to GND Logic level 1: open Wet contact: Logic level 0: 0~3 VDC Logic level 1: 10~30 VDC |
| Keep/Discard Counter Value when power off |
- |
| Supports Inverted DI Status |
- |
| Transition Time |
0.2 ms |
| Wet Contact |
Logic 0: 0 ~ 3 VDC or 0 ~ -3 VDC, Logic 1: 10 ~ 30 VDC or -10 ~ -30 VDC, (Dry/Wet Contact decided by Switch) |
| Environment |
| Humidity (Operating) |
20 ~ 95% RH (non-condensing) |
| Operating Temperature |
-10 ~ 70°C (14 ~ 158°F) |
| Storage Humidity |
0 ~ 95% RH (non-condensing) |
| Storage Temperature |
-20 ~ 80°C (-4 ~ 176°F) |
| General |
| Connector |
Plug-in 5P/15P screw terminal blocks |
| Dimensions |
110 x 60 x 27 mm |
| Ethernet |
2-port 10/100 Base-TX (for Daisy Chain) |
| LED Indicators |
4 RL + 4 DI |
| Power Consumption |
4.2 W @ 24 VDC |
| Power Input |
10 - 30 VDC (24 VDC standard) |
| Protection |
Built-in TVS/ESD protection Power Reversal protection Over Voltage protection: +/- 35VDC Isolation protection: 2500 VDC |
| Protocol |
Modbus/TCP, TCP/IP, UDP, HTTP, DHCP |
| Watchdog Timer |
System (1.6 second) & Communication (programmable)
|
| Relay Output |
| Breakdown Voltage |
500 VAC (50/60Hz) |
| Channels |
4 Form C |
| Contact Rating |
250 VAC @ 5A 30 VDC @ 5A |
| Frequency of Operation |
360 operations/hour with load, 72,000 operations/hour without load |
| Insulation Resistance |
> 10 GΩ @ 500 VDC |
| Isolation between Contact |
1000 Vrms |
| Max. Breakdown Capacity |
1250 VA |
| Max. Switching Voltage |
400 VAC, 300 VDC |
| Set/Reset Time |
8 ms/8 ms |
|
|