TECHNOLOGY |
Standards |
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX, IEEE802.3x |
Protocols |
Transparent to higher layer protocols |
Processing Type |
Half-duplex back-pressure and IEEE802.3x Full-duplex flow control |
Forward and Filtering Rate |
14,880pps for 10Mbps; 148,810pps for 100Mbps |
INTERFACE |
Ethernet Port |
Port: One RJ-45 port
• Speed: 10/100Mbps
• Distance: 100 meters (328ft.)
• Cable: 10BASE-T:
UTP CAT. 3, 4, 5 (2-pair wire)
100BASE-TX: UTP CAT. 5 (4-pair wire)
|
Extender Port |
Port: One RJ-11 and Terminal Block port
• Speed: Up to 100Mbps
• Distance: up to 2600 meters (8530 ft.)
• Cable: Telephone wire 24 AWG
(0.5mm diameter, 1-pair wire) or larger |
DIP Switch |
DIP 1 Site: Auto/Loc
DIP 2 LDR: ON/OFF |
LED Indicators |
Per Unit: Power 1, 2
Per 10/100TX Port: Link/Activity, Full-duplex
Line Speed: 100/80/60/40/20Mbps and Link below 20Mbps |
Cable |
62.5 / 125 µm |
Connector |
SC or ST |
Range |
2 km (1.2 miles) |
|
MESR9xx-Sx40 |
Type / Wavelength |
Single-mode / 1310 nm |
Output Power |
(-)5 to 0 dBm |
Receive Sensitivity |
~ (-) 34 dBm |
Cable |
9 / 125 µm |
Connector |
SC or ST |
Range |
40 km (5 miles) |
POWER |
Input Voltage |
12 to 48VDC (Terminal Block) |
Power Consumption |
4.56W max. 0.38A @ 12VDC - 0.07A @ 48VDC |
Protection |
Over current protection
Reverse polarity protection |
MECHANICAL
|
Enclosure |
Aluminum case IP30 |
Dimensions |
42mm (W) x 90mm (D) x 100mm (H) (1.65” (W) x 3.54” (D) x 3.94” (H)) |
Weight |
0.41 Kg (0.9 lbs.) |
Installation |
DIN-Rail (Top hat type 35mm) mounting |
ENVIRONMENTAL |
Operating Temperature |
-40°C to 75°C (-40°F to 167°F) |
Storage Temperature |
-40°C to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5% to 95% (non-condensing) |
Regulatory Approvals |
ISO |
Manufactured in an ISO9001 facility |
Safety |
UL60950-1, EN60950-1, IEC60950-1 |
EMI |
FCC Part 15B, Class A
VCCI Class A
EN61000-6-4 |
EMS |
EN61000-6-2
• EN61000-4-2 (ESD Standards)
• EN61000-4-3 (Radiated RFI Standards)
• EN61000-4-4 (Burst Standards)
• EN61000-4-5 (Surge Standards)
• EN61000-4-6 (Induced RFI Standards)
• EN61000-4-8 (Magnetic Field Standards) |
Environmental |
IEC60068-2-6 Fc (Vibration Resistance)
IEC60068-2-27 Ea (Shock)
FED STD 101C Method 5007.1 (Free fall w/ package) |