Serial interface |
Interface 1 |
Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
Connection method |
Push-in connectionRJ45 socket |
Transmission length |
100 m (including patch cables) |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
1.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
1.5 mm² |
Conductor cross section AWG min. |
26 |
Conductor cross section AWG max. |
16 |
Wire diameter incl. insulation |
|
Pin assignment |
1:1 |
Serial transmission speed |
10/100/1000 Mbps |
Output nominal voltage |
< 60 V (ATEX approval) |
|
< 57 V DC (With UL approval) |
Maximum output current |
725 mA (Per channel) |
Maximum output power |
60 W |
Interface 2 |
Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
Connection method |
RJ45 CAT5e |
Stripping length |
8 mm |
Torque |
|
Ambient conditions |
Ambient temperature (operation) |
-40°C ... 75°C |
Ambient temperature (storage/transport) |
-40°C ... 85°C |
Permissible humidity (operation) |
10 % ... 95 % (non-condensing) |
Altitude |
5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval) |
Degree of protection |
IP20 (Manufacturer's declaration) |
General |
Net weight |
124.2 g |
Housing material |
Plastic |
Color |
Gray |
MTTF |
105699 Years |
Degree of pollution |
2 |
Overvoltage category |
II |
Conformance |
CE-compliant |
ATEX |
II 3 G Ex nA IIC Gc U |
UL, USA |
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, Canada |
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Standards and Regulations |
Type of test |
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result |
10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g |
Type of test |
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result |
30g for 11 ms, three shocks in each spatial direction |
Type of test |
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 |
Test result |
10g for 16 ms, 1000 shocks in each spatial direction |
Rated insulation voltage |
85 V DC |
Conformance |
CE-compliant |
ATEX |
II 3 G Ex nA IIC Gc U |
UL, USA |
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, Canada |
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Noxious gas test |
ISA-S71.04-1985 G3 Harsh Group A |
Dimensions |
Caption |
Compact housing |
Width |
23.8 mm |
Height |
101.3 mm |
Depth |
50 mm |
Approvals |
|
Environmental Product Compliance |
China RoHS |
Environmentally friendly use period: unlimited = EFUP-e |