| Ethernet |
| Port |
1 port RJ45 – 10/100 Base-TX - Shielded |
| Auto-MDIX |
Auto-MDIX enables proper operation with either straight-through or crossover cabling |
| Distance |
Distance up to 100 meters ( 328 feet ) as per IEEE 802.3 |
| Maximum Frame Size |
1522 bytes |
| VDSL – Interlink |
| RJ45, BNC, Terminal Block |
TIP and RING are polarity insensitive. Surge suppresion of 400 volts between TIP and RING
Choice of RJ45, BNC or terminal block models for VDSL link connector
- RJ45 – RING pin 4, TIP pin 5 (TIA 568 A/B)
- BNC – Coaxial 75 ohm cable with BNC connector
- Terminal Block – 2 position screw connectors for use with twisted pair telephone cabling
|
| Cabling |
Ethernet Extenders must be connected in pairs using unconditioned wire between 19 ( 0.9 mm ) and 26 AWG ( 0.44 mm ). Circuits that run through signal equalization equipment are not permitted. |
| VDSL2 Line Rate/Reach |
Actual distance and rates experienced will depend on condition and guage of wire used. This Rate/Reach table applies to 24 AWG ( 0.5 MM ) twisted pair wiring on RJ45 (RJ) and terminal block (TB) models.
| High Speed Asymmetric |
| Reach ( Distance ) |
VDSL Rate ( Mbps ) |
| feet |
meters |
Downstream |
Upstream |
| 500 |
152 |
101 |
92 |
| 1000 |
305 |
101 |
63 |
| 1500 |
457 |
90 |
38 |
| 2000 |
610 |
62 |
24 |
| 2500 |
762 |
55 |
10 |
| 3000 |
914 |
42 |
5 |
| 3500 |
1000 |
35 |
3 |
| High Speed Symmetric |
| Reach ( Distance ) |
VDSL Rate ( Mbps ) |
| feet |
meters |
Downstream |
Upstream |
| 500 |
152 |
101 |
101 |
| 1000 |
305 |
85 |
101 |
| 1500 |
457 |
62 |
47 |
| 2000 |
610 |
60 |
29 |
| 2500 |
762 |
44 |
14 |
| 3000 |
914 |
30 |
7 |
| 3500 |
1000 |
29 |
4 |
| Long Reach Symmetric |
| Reach ( Distance ) |
VDSL Rate ( Mbps ) |
| feet |
meters |
Downstream |
Upstream |
| 500 |
152 |
53 |
44 |
| 1000 |
305 |
53 |
43 |
| 2500 |
762 |
39 |
18 |
| 4000 |
1219 |
25 |
4 |
| 5500 |
1676 |
17 |
1.9 |
| 7000 |
2134 |
8 |
2.3 |
| 7500 |
2286 |
7 |
2.2 |
| 8000 |
2438 |
5 |
2.2 |
| Long Reach Asymmetric |
| Reach ( Distance ) |
VDSL Rate ( Mbps ) |
| feet |
meters |
Downstream |
Upstream |
| 500 |
152 |
78 |
16 |
| 1000 |
305 |
78 |
16 |
| 2500 |
762 |
55 |
10 |
| 4000 |
1219 |
31 |
0.8 |
| 5500 |
1676 |
20 |
0.6 |
| 7000 |
2134 |
11 |
0.6 |
| 7500 |
2286 |
10 |
0.6 |
| 8000 |
2438 |
8 |
0.6 |
|
| Chassis Module |
| Compatible chassis |
Module occupies a single slot in MCR1900 or MCR200 chassis |
| Indicators |
| Power / TST |
This green LED is turned on when power is applied to the Ethernet Extender. Otherwise it is off. The LED will blink when in Loopback test mode. |
| CO - Local |
Ethernet Extender is operating in CO VDSL mode |
| CPE - remote |
Ethernet Extender is operating in CPE VDSL mode |
| ILNK |
Indicates Link Status and activity on the Interlink (VDSL) port |
| ETH |
Indicates link status and activity on Ethernet port. |
| Switches – On-board PCB |
| Rate/Reach |
Two switches enable the user to select the right balance between speed and distance for their environment. |
| Signal to Noise Ratio |
Selectable Signal to Noise Ratio (SNR) of 6dB or 9dB. The higher SNR number provides better impulse noise protection but lowers performance. |
| Auto-Negotiation (802.3u) |
Enabled (Default) - The Ethernet Extender uses 802.3u Auto-negotiation on the 10/100Base-TX interface. It is set to advertise full duplex.
Disabled - The Ethernet Extender sets the port according to the position of the speed and duplex switches. |
| Link Mode |
Standard (Default) – The 10/100Base-TX link remains active independent of the state of the Ethernet link on its remote peer.
Link Pass-Through- state of the 10/100Base-TX Ethernet connection is “passed through” or propagated across the VDSL link to the 10/100Base-TX Ethernet link on its remote Ethernet Extender peer. This enables a managed switch to report the state of the remote device to its network management system. |
| Interlink Fault Feedback |
Enabled - A loss of VDSL link will drop the 10/100 Ethernet port on each end until the link recovers
Disabled ( Default ) – The state of the VDSL link is not propagated to the 10/100Base-TX port |
| Loopback |
Enabled - The VDSL interlink will perform a loopback function, retransmitting all received Ethernet frames back to its peer.
Disabled (Default - Up) |
| Set Ethernet Speed |
When Auto-Negotiation switch is disabled, fixed speed can be set to 100 (Default) or 10 |
| Set Ethernet Duplex |
When Auto-Negotiation switch is disabled, Duplex can be set to Full (Default) or Half |
| Environmental Specifications |
| Operating Temperature |
0 C to 50 C (32 F to 122 F) |
| Storage Temperature |
minimum range of -25 C to 70 C (-13 F to 158 F) |
| Operating Humidity |
5% to 90% non-condensing |
| Storage Humidity |
5% to 95% non-condensing |
| Operating Altitude |
Up to 3,048 meters (10,000 feet) |
| Heat Output ( BTU/HR ) |
13.1 |
| Power Consumption ( Watts ) |
3.8 |
| MTBF (Hours)* |
466,387 |
| Packaging |
| Shipping Weight |
0.25 kg, 0.55 lbs |
| Shipping Dimensions |
150 x 210 x 40 mm, 5.9 x 8.3 x 1.6 inches |
| Regulatory Approvals |
| Emissions |
FCC Part 15 Class A, EN55022 Class A |
| CISPR 22 Class A |
| EN61000-3-2 |
| Immunity |
EN55024 |
| Electrical Safety |
UL 60950-1 |
| EN60950 |
| CE |
| Environmental |
Reach, RoHS and WEEE Compliant |
| Other |
ECCN: 5A991A |
| HTSUS Number: 8517.62.0050 |
| Perle Lifetime warranty |