GNL1025P - 615W 1025VA GNL-P Series 6-Outlet Line Interactive Uninterruptable Power Supply by OPTI-UPS
|
|
|
- LINE mode indicator (Green)
- AVR Boost / Buck mode indicator (Yellow)
- OVER LOAD indicator (Red)
- Full-time Battery Backup and Surge Protected Outlets
Compact size with multiple outlets for full-time battery backup & surge protection
- AVR Technology
Boost and buck AVR for voltage stabilization
- RJ11 / RJ45 Surge Protection
1-in and 1-out surge protection port
- USB Connectivity
Allows computer to communicate with UPS through USB port
- Perfect Autonomy
This UPS offers power protection to your equipment with or without the use of the bundled software
- Professional Management Software
Keeps track of and makes decisions upon various power line events.
- DC power on
Allows UPS to start in the absence of AC grid power
- Supports OPTI-SAFE Sentinel
Microsoft Windows 98, Windows 7, Windows 8, Windows 2000, Windows XP, Windows Vista, Windows Server 2003 and Windows Server 2008
|
|
|
Voltage and frequency fluctuations, surges, sags and power cuts are likely to seriously damage your sensitive equipment. These problems occur every day all over the world, and are more frequent in areas with overloaded power grid systems.
The TS Series are the ideal solution to protect your small office and home office systems (SOHO), as well as other electronic devices, which are needed for daily use. Not only is TS a great value for your money, it also is the UPS that is extremely easy to handle. TS fulfills the requirements of many types of users.
With their built-in batteries, most UPS products can do their jobs. However, the batteries would soon deteriorate if used often. This is where the OPTI-UPS TS Series rise above the others. With there wide range AVR, battery usage is limited to very extreme conditions while normal voltage fluctuations are easily controlled by the UPS. When things get tough on the utility source, the TS Series product line is there to give the right amount of battery backup.
The TS Series product line is your insurance to continuous performance and peace of mind!
MODEL NAME |
GNL1025P |
Topology |
Line-Interactive / Low Frequency |
On-battery Output Waveform |
Simulated Sine Wave |
Maximum Capacity (VA/W) |
1025VA / 615W |
INPUT |
Nominal Input Voltage |
110/120Vac (!!) |
Nominal Input Frequency |
50Hz / 60Hz Auto Sensing |
Input Voltage Range |
Rated Voltage ± 25% |
AC Line-In Plug |
NEMA 5-15P |
|
OUTPUT |
Nominal Output Voltage |
110/120Vac (!!) |
Output Voltage Regulation |
Rated Voltage ± 5% (on battery) |
Transfer Time (Typical) |
4 ms |
Start on Battery |
Yes |
Auto Restart |
Yes |
Automatic Voltage Regulator (AVR) |
AVR increases the output voltage by 15% while the input voltage is below nominal by 9% to 25% |
AVR decreases the output voltage by 13% while the input voltage is above nominal by 9% to 25% |
Type and Number of Outlets |
4 Battery backup + 2 Bypass surge protected outlets |
|
PROTECTION |
Data Line Surge Protection |
RJ11/RJ45 |
Surge Energy Rating |
110/120Vac 1050 Joules |
Overload Protection |
UPS shuts down at overload 10% after
60 secs or at 30% after 3 secs |
Over Current Protection |
Circuit breakers |
BATTERY |
Configuration |
RBAT - 12 |
Typical Backup Time** |
50 min |
Recharge Time to 90% (Typical) |
< 4 Hours |
ADVANCED WARNINGS / DIAGNOSTICS |
Front Panel LEDs |
Power Status / AC mode / Battery Mode / Battery Fault / Overload |
Audible Alarms |
Battery Mode / Battery Low / Overload |
COMMUNICATIONS INTERFACE |
Communication Port |
USB |
ENVIRONMENTAL PARAMETERS |
Operating Temperature |
0°C~40°C / 32°F~104°F |
Storage Temperature |
-20°C~60°C / -4°F~140°F |
Audible Noise |
< 40 dBA |
PHYSICAL PARAMETERS |
Dimensions (LxWxH) |
Physical / Packing |
19.2×10×12.6 inches / 488×253×321 mm |
Weight(Net/Gross) |
lbs |
28 / 33 |
kg |
12.7 / 15 |
CONFORMANCE |
Safety Certifications |
UL / cUL |
|
|