Advantech SMI6-12-V-ST - Power Supply, 12 VDC 6 Watt, Stripped and Tinned, International AC Input by Advantech
|
|
|
- level VI efficiency
- up to 6 W power
- interchangeable AC blades
- universal input (90~264 Vac)
- single regulated output from 5~15 Vdc
- over voltage and short circuit protections
- UL/cUL, GS, RCM, CCC, PSE safety approvals
- custom designs available
|
|
|
CUI Inc. SMI Family Plug Wall Adapters are Ac-Dc power supplies with interchangeable blades. SMI6-12-V-ST are each designed to meet the latest Level VI efficiency standards set to go into effect February 2016. This standard aims to significantly lower the amount of power consumed when the end application is not in use or is no longer connected to the system.
Designed for global use, CUI's SMI6-12-V-ST adapters include plug options for North America, Europe, the United Kingdom, Australia, and China. These high efficiency power supply adapters are a continuation of CUI's initiative to provide customers with global solutions utilizing the latest in green power technology.
INPUT |
|
|
|
|
|
parameter |
conditions/description |
min |
typ |
max |
units |
voltage |
|
90 |
|
264 |
Vac |
frequency |
|
47 |
|
63 |
Hz |
current |
|
|
|
0.3 |
A |
leakage current |
|
|
|
0.25 |
mA |
no load power consumption |
Level VI ErP Tier 2 |
|
|
0.1
0.075 |
W
W |
OUTPUT |
|
|
|
|
|
parameter |
conditions/description |
min |
typ |
max |
units |
line regulation |
5, 9 Vdc models
all other models |
|
±3
±1 |
|
%
% |
load regulation |
|
|
±5 |
|
% |
PROTECTIONS |
|
|
|
|
|
parameter |
conditions/description |
min |
typ |
max |
units |
over voltage protection |
output shut down, auto recovery |
|
|
|
|
short circuit protection |
output shut down, auto recovery |
|
|
|
|
SAFETY & COMPLIANCE |
|
|
|
|
|
parameter |
conditions/description |
min |
typ |
max |
units |
isolation voltage |
input to output at 10 mA for 1 minute |
|
3,000 4,242 |
|
Vac Vdc |
isolation resistance |
input to output at 500 Vdc |
100 |
|
|
MΩ |
safety approvals |
UL/cUL, GS, RCM, CCC, PSE |
|
|
|
|
EMI/EMC |
FCC Part 15B Class B, CE |
|
|
|
|
RoHS |
2011/65/EU |
|
|
|
|
ENVIRONMENTAL |
|
|
|
|
|
parameter |
conditions/description |
min |
typ |
max |
units |
operating temperature |
|
0 |
|
40 |
°C |
storage temperature |
|
-10 |
|
70 |
°C |
operating humidity |
non-condensing |
20 |
|
80 |
% |
storage humidity |
non-condensing |
10 |
|
90 |
% |
MECHANICAL |
|
|
|
|
|
parameter |
conditions/description |
min |
typ |
max |
units |
dimensions |
64 x 40.5 x 30 |
|
|
|
mm |
inlet plug |
interchangeable blades (US, Europe, UK, Australia, China) |
|
|
|
|
weight |
5.95 Vdc model (without interchangeable blades) all other models (without interchangeable blades) |
|
69
68.5 |
|
g
g |
|
|
|
|