Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
MGate 5111-T - 1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateway, -40 to 75 Degreee C  operating temperature by MOXA

MGate 5111-T - 1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateway, -40 to 75 Degreee C operating temperature
by MOXA

Write a review Write a review
  • Supports PROFIBUS DP V0 slave
  • Supports Modbus RTU/ASCII/TCP master or slave
  • Supports EtherNet/IP adapter or PROFINET IO device
  • Built-in traffic monitoring/diagnostics/status monitoring and fault protection
  • Built-in Ethernet cascading for easy wiring
  • Redundant dual DC power inputs and relay output supported
  • MicroSD card for configuration backup/duplication, and event log
  • Serial port with 2 kV built-in isolation protection 
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC-62443

 

Mfg SKU # : MGate 5111-T
Our Price : $761.35
Stock : Call for Availability
Quantity :

MGate 5111 industrial Ethernet gateways convert data between the Modbus RTU/ASCII/TCP, EtherNet/IP, PROFINET, and PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation. Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs. For Sytem integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system. The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications such as factory automation, power, oil & gas, water and wastewater, and other process automation industries.

 

Easy Configuration

The MGate 5111 series gateway has a friendly user interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps. The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, firmware log functions are provided to record connection and Modbus maintenance events, and users can review log data remotely through the web console.

 

Variety of Maintenance Functions

The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, like slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitor, which let you capture and check data to easily identify root causes. MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a pre-defined value set by the user.

Industrial Protocols
Protocols PROFIBUS, Modbus RTU/ASCII/TCP, PROFINET, EtherNet/IP
Protocol Conversion • Modbus RTU/ASCII (Master/Slave) to PROFIBUS slave
• Modbus TCP (Client/Server) to PROFIBUS slave
• EtherNet/IP (Adapter) to PROFIBUS slave
• PROFINET (IO Device) to PROFIBUS slave
 Ethernet Interface
Protocols Modbus TCP (Client/Server), PROFINET (IO device), EtherNet/IP (Adapter)
Number of Ports 2 (1 IP address, supports Ethernet cascading)
Speed 10/100 Mbps, Auto MDI/MDIX
Connector 8-pin RJ45
Magnetic Isolation Protection 1.5 kV (built-in)
 PROFIBUS Interface
Protocol PROFIBUS DP-V0 Slave
Number of Ports 1
Data Rate 9600 bps to 12 Mbps
Connector DB9 female
Isolation 2 kV (built-in)
Rotary Switch PROFIBUS address 0-99 (address 100-125 supported through software configuration)
 Modbus Serial Interface
Protocols Modbus RTU/ASCII (Master/Slave)
Number of Ports 1
Serial Standards RS-232/422/485, software selectable
Connectors DB9 male
Pull High/Low Resistor for RS-485 1 kΩ, 150 kΩ
Terminator for RS-485 120 Ω
Isolation 2 kV (built-in)
 Modbus Serial Communication Parameters
Data Bits 8
Stop Bits 1, 2
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS, RTS Toggle (RS-232 only)
Baudrate 50 bps to 921.6 kbps
 Modbus Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
 Modbus TCP Interface
Protocols Modbus TCP client/server
Functions Supported 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. Number of Commands 128
Max. Number of Connections • MGate as Modbus TCP Client: 32 connections
• MGate as Modbus TCP Server: 16 connections
Max. Total I/O Data Size Input: 2048 bytes, Output: 2048 bytes
 EtherNet/IP Interface
Class Adapter
CIP Objects Supported Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port
Max. Number of Connections • MGate as Adapter:
1 connection for read/write
1 connection for read-only
• Max. Total I/O Data Size:
Input: 496 bytes
Output: 496 bytes
 PROFINET Interface
Protocol PROFINET RT IO Device
Memory Input 512 bytes/output 512 bytes
Maximum No. of Connections 1 master connection
 Software
Configuration Options Web console
Utility Device Search Utility (DSU) for Windows 95, 98, ME, NT, 2000, Windows XP, Server 2003, Vista, Server 2008 (x86/x64), Windows Server 2008 R2, Windows 7/8/8.1/10 (x86/x64), Windows Server 2012 (x64), Windows 2012 R2
Network Protocols TCP/IP, UDP, HTTP, HTTPS, SMTP, NTP, DNS, DHCP Client, SNMP (v1, v2c, v3), MIB-II, ARP, Telnet, SSH
Support MXview, MXconfig
 Physical Characteristics
Housing Metal, IP30
Weight 589 g (1.30 lb)
Dimensions 45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)
Storage Card Slot 1 microSD (SDHC) card slot; supports up to 32 GB
Relay Alarm Circuit 3-pin circuit with current carrying capacity of 2 A @ 30 VDC
 Environmental Limits
Operating Temperature Standard Models: 0 to 60°C (32 to 140°F) 
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Vibration IEC 60068-2-6, IEC 60068-2-64
Shock IEC 60068-2-27
Drop IEC 60068-2-32
 Power Requirements
Input Voltage 12 to 48 VDC
Input Current • 460 mA @ 12 VDC
• 221 mA @ 24 VDC
• 121 mA @ 48 VDC
Power Connector Terminal block
 Standards and Certifications
Safety EN 60950-1(LVD), UL 61010-2-201
Hazardous Location Class I Division 2, ATEX, IECEx
EMC EN 61000-6-2/6-4
EMI CISPR 22, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m
IEC 61000-4-8 PFMF: 30 A/m
 Reliability
Alarm Functions Relay, email, SNMP trap
Alert Tools Built-in buzzer
 MTBF (mean time between failures)
Time 718,131 hrs
Standard Telcordia SR332
Related Items

Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.