MGate 5121-T - 1-port CANopen/J1939-to-Modbus TCP gateways, -40 to 75C operating temperature by MOXA
|
|
|
MGate 5121-T_SUMMARY.html
- Simultaneous protocol conversions from CANopen and J1939 to Modbus TCP and SNMP
- Supports Modbus TCP server and SNMP agent
- Supports CANopen master and J1939
- Flexible deployment with Ethernet cascading and dual subnet
- Embedded traffic monitoring/diagnostic information for easy troubleshooting
- Easy device configuration via a web-based console
- microSD card for configuration backup/duplication
- Supports dual redundant DC power inputs and 1 relay output
- CAN port with 2-kV isolation protection
- -40 to 75C wide operating temperature models available
- Developed according to IEC 62443-4-2 with Secure Boot
|
|
|
MGate 5121-T_DESCRIPTION.html
MGate 5121-T - The MGate 5121 is an industrial Ethernet gateway for
converting CANopen or J1939 to Modbus TCP network communications.
To integrate existing CANopen or J1939 devices onto a Modbus TCP network,
use the MGate 5121 as a CANopen or J1939 master to collect data and
exchange data with the Modbus TCP host. All models are protected by
a rugged and compact metal housing and are DIN-rail mountable. The
rugged design is suitable for industrial applications such as factory
automation and other process automation industries.
MGate 5121-T.html
Ethernet Interface -
10/100BaseT(X) Ports (RJ45 connector) - 2
Auto MDI/MDI-X connection -
Magnetic Isolation Protection Ethernet Software Features -
Industrial Protocols -
Configuration Options - Web Console (HTTPS)
Device Search Utility (DSU) -
Management - ARP
DHCP Client DNS HTTP HTTPS SMTP SNMP Trap SNMPv1/v2c/v3 TCP/IP UDP -
MIB -
Time Management Security Functions -
Authentication -
Encryption - HTTPS
AES-128 AES-256 SHA-256 -
Security Protocols - SNMPv3
SNMPv2c Trap HTTPS (TLS 1.3) CAN Interface -
No. of Ports -
Connector - Spring-type Euroblock terminal
-
Standards -
Baudrate - CANopen: 10 kbps, 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps, 1 Mbps
J1939: 250 kbps, 500 kbps, 1 Mbps
-
Terminator - 120 ohms
software configurable -
Signals - CAN_H, CAN_L, GND, Ext_CAN_H, Ext_CAN_L, CAN_Shield
CAN Software Features CANopen -
Mode -
Max No. of Nodes -
Max No. of Receive PDOs -
Max No. of Transmit PDOs -
SDOs -
Input Data Size -
Output Data Size J1939 -
Max. No. of Commands -
Input Data Size -
Output Data Size Modbus TCP -
Mode -
Functions Supported - 1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Client Connections -
Total Input Data Size -
Total Output Data Size Memory -
microSD Slot - Up to 32 GB (SD 2.0 compatible)
Power Parameters -
Input Voltage -
Input Current -
Power Connector - Spring-type Euroblock terminal
Relays -
Contact Current Rating - Resistive load: 2 A @ 30 VDC
Physical Characteristics -
Housing -
IP Rating -
Dimensions - 25 x 90 x 129.6 mm (0.98 x 3.54 x 5.1 in)
-
Weight Environmental Limits -
Operating Temperature -
Storage Temperature (package included) -
Ambient Relative Humidity - 5 to 95% (non-condensing)
Standards and Certifications -
Safety - EN 61010-2-201
UL 61010-2-201 -
EMC -
EMI -
EMS - IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m IEC 61000-4-8 PFMF -
Freefall -
Shock -
Vibration - IEC 60068-2-6
IEC 60068-2-64 MTBF
|
|