					| ICP DAS ZT-2053 - 14 Digital Inputsby  ICP DAS
 |  |  |  
					|  |  ZigBee Wireless Module with 14 Digital Input Channels for dry or wet contact. Supports DCON and Modbus RTU Protocols. Its effective distance for dry contact is up to 500 meters (RoHS) (Long Range).   |  |  |  |  
    | 
	
		
		
The ZT-2053 offers 14 digital input channels which can be used for either dry or wet contact. Its effective distance for dry contact is up to 500 meters. All channels are able to be used as 16-bit counters. The ZT-2053 includes 14 LED indicators to display the channel status as well as 4 kV ESD protection and 3750 Vrms intra-module isolation. Users can easily to configure the module address, protocol, checksum, ZB-PID and ZB-channel settings using a combination of rotary and DIP switches.
 
  ISM 2.4 GHz Operating FrequencyFully Compliant with 2.4G /ZigBee Specifi cationsWireless Transmission Range up to 700 mGUI Confi guration Software (Windows Version)14 Dry or Wet Contact Digital Input ChannelsSupports 16-bit Counters for Digital Input ChannelsSurge and ESD ProtectionDIN-Rail Mountable   
Specifications
  
    
      | Communication Interface |  
      | Wireless Standards | ZigBee 2007 Pro |  
      | Transmission Power | 11dBm (FCC Certificated) (Max 19dBm) |  
      | 2.4 GHz Antenna | 5 dBi Omni directional |  
      | Transmission Range (LoS) | 700 m (Typical) |  
      | Certification | Yes - CE/FCC, FCC ID |  
      | Max. Slaves in ZigBee Network | 255 |  
      | ZB-100R/ZB-100T Support | - |  
      | Protocols | Supports DCON and Modbus RTU Protocols |  
      | How Swap | Rotary and DIP switch |  
      | LED Indicators |  
      | Power | 1 LED, Red |  |
 
      | ZigBee Communications | 1 LED, Green |  
      | Digital Input and Output | 14 LEDs, green |  
      | Isolation |  
      | Intra-module Isolated, Field-to-Logic | 3750 VDC |  
      | EMS Protection |  
      | ESD (IEC 61000-4-2) | 4 kV Contact for Power Line, Communication Line and each Channel, 8 kV Air for Random Point |  
      | EFT (IEC 61000-4-4) | 4 kV for Power |  
      | Surge (IEC 61000-4-5) | 3 kV for Power |  
      | Power |  
      | Power Consumption | 0.72 W Max |  
      | Mechanical |  
      | Flammability | Fire Retardant materials (UL94-V0 Level) |  
      | Dimensions (W x L x H) | 33 mm x 87 mm x 107 mm |  
      | Installation | DIN-Rail |  
      | Environment |  
      | Operating Temperature | -25 ~ +75°C |  
      | Storage Temperature | -30 ~ +80°C |  
      | Relativel Humidity | 10 ~ 90% RH, Non-condensing |  I/O Specifications
  
    
      | Digital Input/Counter |  
      | Input Channels | 14 |  
      | Input Types | Source |  
      | Sink/Source |  
      | Wet Contact | On Voltage Level: +3.5 VDC ~ +30 VDC |  
      | Off Voltage Level: +1 VDC Max. |  
      | Dry Contact (Sink) | On Voltage Level: Close to GND |  
      | Off Voltage Level: Open |  
      | Effective Distance for Dry Contact: 500 m Max. |  
      | Counter | Channels: 14 |  
      | Max. Count: 16-bit (65535) |  
      | Max. Input Frequency: 100 Hz |  
      | Min. Pulse Width: 5 ms |  
      | Impedence | 3 kΩ, 0.33 W |  |  
    |  |  
    |  |  
 |