TCC-100I - Industrial RS-232/422/485 Converter. 2KV Isolation by MOXA
|
|
|
- RS-232 to RS-422 conversion with RTS/CTS support
- RS-232 to 2-wire or 4-wire RS-485 conversion
- 2 kV isolation protection (TCC-100I)
- Wall and DIN-Rail mounting
- Plug-in terminal block for easy RS-422/485 wiring
- LED indicators for power, Tx, Rx
- Wide temperature model available (-40 to 85°C)
|
|
|
The TCC-100/100I series RS-232 to RS-422/485 converters increase networking capability by extending the RS-232 transmission distance. Both converters have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, external terminal block for power, and optical isolation (TCC-100I and TCC-100I-T only). The TCC-100/100I series converters are ideal solutions for converting RS-232 signals to RS-422/485 in critical industrial environments.
• RS-232 Side |
Connector |
DB9 female |
Signals |
TxD, RxD, RTS, CTS, GND |
• RS-422/485 Side |
Connector |
Terminal Block |
Signals |
(interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, RTS, CTS, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w: Data+, Data-, GND |
RS-485 Data Direction Control |
ADDC® (automatic data direction control) |
• Serial Communication |
Baudrate |
50 bps to 921.6 kbps |
ESD Protection |
15 kV |
Optical Isolation |
2 kV (TCC-100I/100I-T) |
• Physical Characteristics |
Housing |
Metal |
Dimensions |
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in) |
Weight |
148 ± 5 g |
• Environmental Limits |
Operating Temperature |
Standard Models: -20 to 60°C (-4 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Power Requirements |
Source of Input Power |
Power input jack |
Input Voltage |
12 to 48 VDC |
Power Consumption |
TCC-100/100-T: 85 mA @ 12 V
TCC-100I/100I-T: 150 mA @ 12 V |
Voltage Reversal Protection |
Protects against V+/V- reversal |
Over Current Protection |
Protects against two signals shorted together |
• Standards and Certifications |
Safety |
UL 60950-1 |
EMC |
CE, FCC |
EMI |
FCC Part 15 Subpart B Class B |
EMS |
IEC 61000-4-2 (ESD) Level 2,
IEC 61000-4-3 (RS) Level 2,
IEC 61000-4-4 (EFT) Level 2,
IEC 61000-4-5 (Surge) Level 2,
IEC 61000-4-6 (CS) Level 2,
IEC 61000-4-8 (SFMF) Level 1 |
Green Product |
RoHS, CRoHS, WEEE |
• MTBF (mean time between failures) |
Time |
3,017,857 hrs |
Database |
MIL-HDBK-217F |
|
|