• Cellular Interface |
Standards |
GSM/GPRS/EDGE/UMTS/HSPA |
Band Options |
• Five-band UMTS/HSPA 800/850/AWS/1900/2100 MHz
• Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz |
HSPA Data Rate |
14.4 Mbps DL, 5.76 Mbps UL |
EDGE Multi-slot Class |
Class 12 |
EDGE Data Rate |
237 Kbps DL, 237 Kbps UL |
EDGE Terminal Device Class |
Class B |
GPRS Multi-slot Class |
Class 12 |
GPRS Data Rate |
85.6 Kbps DL, 85.6 Kbps UL |
GPRS Terminal Device Class |
Class B |
GPRS Coding Schemes |
CS1 to CS4 |
Tx Power |
UMTS/HSPA: 0.25 W
EDGE900: 0.5 W
EDGE1800: 0.4 W
GSM1800: 1 W
GSM900: 2 W |
• WAN Interface |
Number of Ports |
1 |
Ethernet |
10/100 Mbps, RJ45 connector, Auto MDI/MDIX |
• LAN Interface |
Number of Ports |
4 |
Ethernet |
10/100 Mbps, RJ45 connector, auto MDI/MDIX |
• SIM Interface |
Number of SIMs |
2 |
SIM Control |
3 V |
• I/O Interface (OnCell 5104-HSPA) |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs |
2 electrically isolated inputs
• +13 to +30 V for state “1” (On)
• +3 to -30 V for state “0” (Off) |
• Software |
Network Protocols |
ARP, DDNS, DHCP/BOOTP, DNS Relay, HTTP, HTTPS, ICMP, IPSec, PPP, PPPoE, SMTP, SNTP, SSL, TCP/IP, Telnet, UDP |
Routing/Firewall |
NAT, port forwarding, WAN IP filtering, static route |
Authentication |
Local user-name and password |
Cellular Connectivity |
GuaranLink |
• Management Software |
Utilities |
OnCell Search Utility |
Configuration and Management Options |
SNMP v1/v2c/v3, Web/Telnet/Serial Console, SSH, Remote SMS Control, Auto IP Report |
Private IP Solution |
OnCell Central Manager |
• Physical Characteristics |
Housing |
Aluminum, providing IP30 protection |
Weight |
OnCell 5004-HSPA: 505±5 g
OnCell 5104-HSPA: 645±5 g |
Dimensions |
OnCell 5004-HSPA: 158 x 103 x 34 mm (6.22 x 4.06 x 1.34 in)
OnCell 5104-HSPA: 135 x 50.8 x 103 mm (5.315 x 2.00 x 4.16 in) |
• Environmental Limits |
Operating Temperature |
Standard Models: -30 to 55°C (-22 to 131°F)
Wide Temp. Models: -30 to 70°C (-22 to 158°F) |
Storage Temperature |
-40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity |
5 to 95% (30°C, non-condensing) |
• Power Requirements |
Number of Power Inputs |
OnCell 5004-HSPA: 1 terminal block, 1 power jack
OnCell 5104-HSPA: 10-pin terminal block with dual power input |
Input Voltage |
12 to 48 VDC |
Power Consumption |
OnCell 5004-HSPA: 12 to 48 VDC, 400 mA (idle), 900 mA (max.)
OnCell 5104-HSPA: 12 to 48 VDC, 450 mA (idle), 950 mA (max.) |
• Standards and Certifications |
Safety |
UL 60950-1 |
EMC |
FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 55024 |
Radio |
FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 489-24, EN 301 511, EN 301 908 |
• Reliability |
MTBF (mean time between failures) |
OnCell 5004-HSPA: 441,000 hrs
OnCell 5104-HSPA: 411,000 hrs |