Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
OnCell 5104-HSPA - 4 port Five-band industrial UMTS/HSPA+ Router, IA design, -30 to 55  Degree C by MOXA

OnCell 5104-HSPA - 4 port Five-band industrial UMTS/HSPA+ Router, IA design, -30 to 55 Degree C
by MOXA

Write a review Write a review
  • Five band UMTS/HSPA 800/850/AWS/1900/2100 MHz
  • Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
  • Cellular WAN and Ethernet WAN backup mechanism for a complete path redundancy
  • Primary and secondary power inputs for power source redundancy
  • GuaranLink and dual SIM redundancy for continuous cellular connections
  • Connect to 4 10/100BaseT(X) devices over an integrated VPN
  • Centralize private IP management with OnCell Central Manager
  • DIN rail and wall mountable housing
  • 2 digital inputs and 1 relay output (OnCell 5104-HSPA only)
  • Introduction 

    The OnCell 5004/5104-HSPA series are high-performance industrial grade cellular routers that allow up to 4 Ethernet-based devices to simultaneously use a single cellular data account for primary or backup network connectivity to remote sites and devices. Both products provide the functionality of a cellular router, firewall, and switch in one device, and to ensure zero data loss and on-demand cellular communication, the OnCell 5004/5104-HSPA are integrated with the GuaranLink function. The difference between the OnCell 5004-HSPA and OnCell 5104-HSPA is that the OnCell 5104-HSPA comes with a built-in relay output that can be configured to indicate the priority of events when notifying or warning engineers in the field, and the two digital inputs allow you to connect basic I/O devices, such as sensors, to the cellular network. The OnCell 5004-HSPA can be placed on a desktop or wall-mounted, whereas the OnCell 5104-HSPA has an IA design and can be attached to a DIN-rail. Both products use 12 to 48 VDC power inputs with a screw-on design for greater reliability, and the Ethernet ports come with 1.5 KV magnetic isolation protection to keep your system safe from unexpected electrical discharges.

     Cellular Interface
    Standards GSM/GPRS/EDGE/UMTS/HSPA
    Band Options • Five-band UMTS/HSPA 800/850/AWS/1900/2100 MHz
    • Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
    HSPA Data Rate 14.4 Mbps DL, 5.76 Mbps UL
    EDGE Multi-slot Class Class 12
    EDGE Data Rate 237 Kbps DL, 237 Kbps UL
    EDGE Terminal Device Class Class B
    GPRS Multi-slot Class Class 12
    GPRS Data Rate 85.6 Kbps DL, 85.6 Kbps UL
    GPRS Terminal Device Class Class B
    GPRS Coding Schemes CS1 to CS4
    Tx Power UMTS/HSPA: 0.25 W
    EDGE900: 0.5 W
    EDGE1800: 0.4 W
    GSM1800: 1 W
    GSM900: 2 W
     WAN Interface
    Number of Ports 1
    Ethernet 10/100 Mbps, RJ45 connector, Auto MDI/MDIX
     LAN Interface
    Number of Ports 4
    Ethernet 10/100 Mbps, RJ45 connector, auto MDI/MDIX
     SIM Interface
    Number of SIMs 2
    SIM Control 3 V
     I/O Interface (OnCell 5104-HSPA)
    Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC
    Digital Inputs 2 electrically isolated inputs
    • +13 to +30 V for state “1” (On)
    • +3 to -30 V for state “0” (Off)
     Software
    Network Protocols ARP, DDNS, DHCP/BOOTP, DNS Relay, HTTP, HTTPS, ICMP, IPSec, PPP, PPPoE, SMTP, SNTP, SSL, TCP/IP, Telnet, UDP
    Routing/Firewall NAT, port forwarding, WAN IP filtering, static route
    Authentication Local user-name and password
    Cellular Connectivity GuaranLink
     Management Software
    Utilities OnCell Search Utility
    Configuration and Management Options SNMP v1/v2c/v3, Web/Telnet/Serial Console, SSH, Remote SMS Control, Auto IP Report
    Private IP Solution OnCell Central Manager
     Physical Characteristics
    Housing Aluminum, providing IP30 protection
    Weight OnCell 5004-HSPA: 505±5 g
    OnCell 5104-HSPA: 645±5 g
    Dimensions OnCell 5004-HSPA: 158 x 103 x 34 mm (6.22 x 4.06 x 1.34 in)
    OnCell 5104-HSPA: 135 x 50.8 x 103 mm (5.315 x 2.00 x 4.16 in)
     Environmental Limits
    Operating Temperature Standard Models: -30 to 55°C (-22 to 131°F)
    Wide Temp. Models: -30 to 70°C (-22 to 158°F)
    Storage Temperature -40 to 75°C (-40 to 167°F)
    Ambient Relative Humidity 5 to 95% (30°C, non-condensing)
     Power Requirements
    Number of Power Inputs OnCell 5004-HSPA: 1 terminal block, 1 power jack
    OnCell 5104-HSPA: 10-pin terminal block with dual power input
    Input Voltage 12 to 48 VDC
    Power Consumption OnCell 5004-HSPA: 12 to 48 VDC, 400 mA (idle), 900 mA (max.)
    OnCell 5104-HSPA: 12 to 48 VDC, 450 mA (idle), 950 mA (max.)
     Standards and Certifications
    Safety UL 60950-1
    EMC FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 55024
    Radio FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 489-24, EN 301 511, EN 301 908
     Reliability
    MTBF (mean time between failures) OnCell 5004-HSPA: 441,000 hrs
    OnCell 5104-HSPA: 411,000 hrs

    Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.