EDS-4009-3MST-LV - Managed Ethernet switch with 6 10/100BaseT(X) ports, 3 100BaseFX multi-mode ports with ST connectors by MOXA
|
|
|
- Developed according to the IEC 62443-4-1 and compliant with the IEC 62443-4-2 industrial cybersecurity standards
- Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches) , and RSTP/STP for network redundancy
- Wide range of power input options for flexible deployment
- Compact and flexible housing design to fit into confined spaces
- Supports MXstudio for easy, visualized industrial network management
|
|
|
The EDS-4009-3MST-LV, EDS-4009 Series is a range of 9-port managed Fast Ethernet switches with the option for three 100M ST/SC fiber-optic ports.
Redundant Ethernet technologies such as Turbo Ring, Turbo Chain, and RSTP/STP increase the reliability of your system and improve the availability of your network backbone. The EDS-4009 Series is designed specifically for demanding applications such as video and process monitoring, ITS, and DCS systems, all of which can benefit from a scalable backbone.
The EDS-4009 Series is compliant with the IEC 62443-4-2 and IEC 62443-4-1 Industrial Cybersecurity certifications, which cover both product security and secure development life-cycle requirements, helping our customers meet the compliance requirements of secure industrial network design.
Ethernet Interface
-
10/100BaseT(X) Ports (RJ45 connector)
6
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
-
100BaseFX Ports (multi-mode SC connector)
EDS-4009-3MSC-LV/-HV/-T models: 3
-
100BaseFX Ports (multi-mode ST connector)
EDS-4009-3MST-LV/-HV/-T models: 3
-
100BaseFX Ports (single-mode SC connector)
EDS-4009-3SSC-LV/-HV/-T models: 3
-
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1X for authentication
Ethernet Software Features
-
Filter
GMRP, GVRP, GARP, 802.1Q VLAN, IGMP Snooping v1/v2/v3, IGMP Querier
-
Management
IPv4/IPv6, Flow control, Back Pressure Flow Control, DHCP Server/Client, ARP, RARP, LLDP, Port Mirror, Linkup Delay, SMTP, SNMP Trap, SNMP Inform, SNMPv1/v2c/v3, RMON, TFTP, SFTP, HTTP, HTTPS, Telnet, Syslog, Private MIB
-
MIB
P-BRIDGE MIB, Q-BRIDGE MIB, IEEE8021-SPANNING-TREE-MIB, IEEE8021-PAE-MIB, IEEE8023-LAG-MIB, LLDP-EXT-DOT1-MIB, LLDP-EXT-DOT3-MIB, SNMPv2-MIB, RMON MIB Groups 1, 2, 3, 9
-
Redundancy Protocols
STP, RSTP, Turbo Ring v2, Turbo Chain, Ring Coupling, Dual-Homing, Link Aggregation
-
Security
Broadcast storm protection, Rate Limit, Trust access control, Static Port Lock, MAC Sticky, HTTPS/SSL, SSH, RADIUS, TACACS+, Login and Password Policy
-
Time Management
SNTP, NTP Server/Client, NTP Authentication
-
Protocols
IPv4/IPv6, TCP/IP, UDP, ICMP, ARP, RARP, TFTP, DNS, NTP Client, DHCP Server, DHCP Client, 802.1X, QoS, HTTPS, HTTP, Telnet, SMTP, SNMPv1/v2c/v3, RMON, Syslog
Switch Properties
-
MAC Table Size
16 K
-
Jumbo Frame Size
9.216 KB
-
Max. No. of VLANs
256
-
VLAN ID Range
VID 1 to 4094
-
IGMP Groups
512
-
Priority Queues
4
-
Packet Buffer Size
1 MB
LED Interface
-
LED Indicators
PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNC
Serial Interface
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
USB Interface
-
USB Connector
USB Type A (Reserved)
Input/Output Interface
-
Alarm Contact Channels
1, Relay output with current carrying capacity of 1 A @ 24 VDC
-
Digital Input Channels
1
-
Digital Inputs
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
-
Buttons
Reset button
DIP Switch Configuration
Power Parameters
-
Connection
2 removable 4-contact terminal block(s)
-
Pre-installed Power Module
-LV/-LV-T models: PWR-100–LV
-HV/-HV-T models: PWR-105-HV-I
-
Note
The EDS-4009 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.
For example:
EDS-4009-T + PWR-100–LV = EDS-4009-LV-T
EDS-4009-T + PWR-105-HV-I = EDS-4009-HV-T
If you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4009–LV-T
with the PWR-105–HV-I, refer to the specifications of the EDS-4009–HV-T.
-
Input Voltage
-LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs
-HV/-HV-T models: 110/220 VDC/VAC, Single input
-
Operating Voltage
-LV/-LV-T models: 9.6 to 60 VDC
-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC
-
Input Current
-LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A
-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A
-
Power Consumption (Max.)
EDS-4009-3MSC-LV(-T) models: 9.51 W
EDS-4009-3MSC-HV(-T) models: 12.14 W
EDS-4009-3MST-LV(-T) models: 9.51 W
EDS-4009-3MST-HV(-T) models: 12.17 W
EDS-4009-3SSC-LV(-T) models: 9.51 W
EDS-4009-3SSC-HV(-T) models: 12.34 W
-
Overload Current Protection
Supported
-
Reverse Polarity Protection
Supported
Physical Characteristics
-
IP Rating
IP40
-
Dimensions
EDS-4009-3MSC(-T)/EDS-4009-3SSC(-T) models:
55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)
EDS-4009-3MST(-T) models:
55 x 140 x 132 mm (2.17 x 5.51 x 5.20 in)
-
Weight
EDS-4009-3MSC(-T) models: 821.5 g (1.81 lb)
EDS-4009-3MST(-T) models: 920 g (2.03 lb)
EDS-4009-3SSC(-T) models: 932 g (2.05 lb)
-
Installation
DIN-rail mounting, Wall mounting (with optional kit)
-
Housing
Metal
Environmental Limits
-
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
-
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
-
Industrial Cybersecurity
IEC 62443-4-1
IEC 62443-4-2
-
Safety
UL 61010-2-201, EN 62368-1 (LVD)
-
EMC
EN 55032/35, EN 61000-6-2/-6-4
-
EMI
CISPR 32, FCC Part 15B Class A
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
-
Vibration
IEC 60068-2-6
-
Shock
IEC 60068-2-27
-
Freefall
IEC 60068-2-32
-
Railway
EN 50121-4
-
Traffic Control
NEMA TS2
MTBF
-
Time
EDS-4009-3MSC-LV/-LV-T models: 972,841 hrs
EDS-4009-3MSC-HV/-HV-T models: 482,263 hrs
EDS-4009-3MST-LV/-LV-T models: 972,841 hrs
EDS-4009-3MST-HV/-HV-T models: 482,263 hrs
EDS-4009-3SSC-LV/-LV-T models: 972,841 hrs
EDS-4009-3SSC-HV/-HV-T models: 482,263 hrs
|
|