EDS-4012-4GS-HV - Managed Gigabit Ethernet switch with 8 10-100BaseT(X) ports, 4 100-1000BaseSFP ports, single power supply 110- by MOXA
|
|
|
- Developed according to the IEC 62443-4-1 and compliant with the IEC 62443-4-2 industrial cybersecurity standards
- Support for IEEE 802.3bt PoE for up to 90 W output per port
- Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches) , and RSTP/STP for network redundancy
- Wide range of power input options for flexible deployment
- Compact and flexible housing design to fit into confined spaces
- Supports MXstudio for easy, visualized industrial network management
|
|
|
EDS-4012-4GS-HV_DESCRIPTION.html
The EDS-4012
Series is a range of 12-port managed Fast Ethernet switches with the
option for four 1 Gbps fiber-optic uplink ports. This Series also
offers models with four 10-100BaseT(X) 802.3af (PoE), 802.3at (PoE+),
and 802.3bt-compliant Ethernet PoE port options to connect high-bandwidth
PoE devices.
Ethernet Interface
-
10/100BaseT(X) Ports (RJ45 connector)
EDS-4012-4GS-LV/-HV/-T models: 8
EDS-4012-4GC-LV/-HV/-T models: 8
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
-
PoE Ports (10/100BaseT(X), RJ45 connector)
EDS-4012-8P-4GS-LVA/-LVB/-T models: 8
-
100/1000BaseSFP Ports
EDS-4012-4GS-LV/-HV/-T models: 4
EDS-4012-8P-4GS-LVA/-VB/-T models: 4
-
Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP)
EDS-4012-4GC-LV/-HV/-T models: 4
-
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for flow control
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1X for authentication
Ethernet Software Features
-
Filter
GMRP, GVRP, GARP, 802.1Q VLAN, IGMP Snooping v1/v2/v3, IGMP Querier
-
Management
IPv4/IPv6, Flow control, Back Pressure Flow Control, DHCP Server/Client, ARP, RARP, LLDP, Port Mirror, Linkup Delay, SMTP, SNMP Trap, SNMP Inform, SNMPv1/v2c/v3, RMON, TFTP, SFTP, HTTP, HTTPS, Telnet, Syslog, Private MIB
-
MIB
P-BRIDGE MIB, Q-BRIDGE MIB, IEEE8021-SPANNING-TREE-MIB, IEEE8021-PAE-MIB, IEEE8023-LAG-MIB, LLDP-EXT-DOT1-MIB, LLDP-EXT-DOT3-MIB, SNMPv2-MIB, RMON MIB Groups 1, 2, 3, 9
-
Redundancy Protocols
STP, RSTP, Turbo Ring v2, Turbo Chain, Ring Coupling, Dual-Homing, Link Aggregation
-
Security
Broadcast storm protection, Rate Limit, Trust access control, Static Port Lock, MAC Sticky, HTTPS/SSL, SSH, RADIUS, TACACS+, Login and Password Policy
-
Time Management
SNTP, NTP Server/Client, NTP Authentication
-
Protocols
IPv4/IPv6, TCP/IP, UDP, ICMP, ARP, RARP, TFTP, DNS, NTP Client, DHCP Server, DHCP Client, 802.1X, QoS, HTTPS, HTTP, Telnet, SMTP, SNMPv1/v2c/v3, RMON, Syslog
Switch Properties
-
MAC Table Size
16 K
-
Jumbo Frame Size
9.216 KB
-
Max. No. of VLANs
256
-
VLAN ID Range
VID 1 to 4094
-
IGMP Groups
512
-
Priority Queues
4
-
Packet Buffer Size
1 MB
LED Interface
-
LED Indicators
PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNC
Serial Interface
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
USB Interface
-
USB Connector
USB Type A (Reserved)
Input/Output Interface
-
Alarm Contact Channels
1, Relay output with current carrying capacity of 1 A @ 24 VDC
-
Digital Input Channels
1
-
Digital Inputs
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
-
Buttons
Reset button
DIP Switch Configuration
Power Parameters
-
Connection
2 removable 4-contact terminal block(s)
-
Pre-installed Power Module
-LV/-LV-T models: PWR-100–LV
-HV/-HV-T models: PWR-105-HV-I
-LVA/-LVA-T models: PWR-101-LV-BP-I
-LVB/-LVB-T models: PWR-103-LV-VB-I
-
Note
The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.
For example:
EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-T
EDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-T
If you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-T
with the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.
-
Input Voltage
-LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs
-HV/-HV-T models: 110/220 VDC/VAC, Single input
-LVA/-LVA-T models: 48 VDC, Redundant dual inputs
-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputs
-
Operating Voltage
-LV/-LV-T models: 9.6 to 60 VDC
-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC
-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)
-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)
-
Input Current
-LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A
-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A
-LVA/-LVA-T models: 48 VDC, 5.42 A
-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 A
-
Power Consumption (Max.)
EDS-4012-4GS-LV/-T models: 10.52 W
EDS-4012-4GS-HV-/T models: 12.22 W
EDS-4012-4GC-LV/-T models: 10.7 W
EDS-4012-4GC-HV/-T models: 13.35 W
EDS-4012-8P-4GS-LVA/-T models:
Without PoE: 13.34 W
With PoE: Max. 240 W for total PD power consumption @ 48 VDC input
EDS-4012-8P-4GS-LVB/-T models:
Without PoE: 15.32 W
With PoE:
Max. 180 W for total PD power consumption @ 48 VDC input
Max. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)
Max. 62 W for total PD consumption @ 12 VDC input
-
Max. PoE Power Output per Port
90 W
-
Overload Current Protection
Supported
-
Reverse Polarity Protection
Supported
Physical Characteristics
Environmental Limits
-
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
-
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
-
Industrial Cybersecurity
IEC 62443-4-1
IEC 62443-4-2
-
Safety
UL 61010-2-201, EN 62368-1 (LVD)
-
EMC
EN 55032/35, EN 61000-6-2/-6-4
-
EMI
CISPR 32, FCC Part 15B Class A
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
-
Vibration
IEC 60068-2-6
-
Shock
IEC 60068-2-27
-
Freefall
IEC 60068-2-32
-
Railway
EN 50121-4
-
Traffic Control
NEMA TS2
MTBF
-
Time
EDS-4012-4GC-LV/-T models: 1,036,336 hrs
EDS-4012-4GC-HV/-T models: 497,392 hrs
EDS-4012-4GS-LV/-T models: 874,838 hrs
EDS-4012-4GS-HV/-T models: 456,870 hrs
EDS-4012-8P-4GS-LVA/-T models: 799,780 hrs
EDS-4012-8P-4GS-LVB/-T models: 759,924 hrs
-
Standards
Telcordia SR332
|
|