SDS16C DHV |
Processor |
MPC8349E, 400 Mhz, 750 MIPS |
Memory |
RAM MB |
64 |
Flash MB |
16 |
Interface Ports |
Number of Serial Ports |
16 |
Serial Port Interface |
Software selectable RS232 / RS485 / RS422 DTE on RJ45 - RS485: full and half duplex |
Sun / Solaris |
Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime |
Serial Port Speeds |
50bps to 230Kbps with customizable baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both, None |
Local Console Port |
RS232 on RJ45 with DB9 adapter ( provided ) |
Network |
Dual 10/100/1000-base TX Ethernet RJ45 |
Software selectable Ethernet speed 10/100/1000, Auto |
Software selectable Half/Full/Auto duplex |
Failsafe Alarm Relay |
3A@24v DC. Normally open contacts closed by IOLAN when active and opened upon alarm condition or power failure |
Power |
Power Supply |
Terminal Block with screw terminals accommodating a #6 ring terminal for each power source. Protective cover provided |
Nominal Input Voltage |
125V DC / 250V DC or 100V AC / 240V AC |
Input Voltage Range |
88-300V DC or 85-265V AC |
AC Input Frequency |
47-63Hz |
Current Consumption @ 125v DC (Amps) |
0.08 |
Current Consumption @ 250v DC (Amps) |
0.05 |
Current Consumption @ 115v AC (Amps) |
0.2 |
Current Consumption @ 230v AC (Amps) |
0.14 |
Current Consumption @ 18v DC (Amps) |
N/A |
Current Consumption @ 24v DC (Amps) |
N/A |
Current Consumption @ 48v DC (Amps) |
N/A |
Current Consumption @ 72v DC (Amps) |
N/A |
Typical Power Consumption (Watts) |
12.5 |
Chassis Ground |
Grounding screw for a #10 ring terminal |
Indicators |
LEDs |
Power |
System Ready |
Network Link activity |
Serial: Transmit and Receive data per port |
Environmental Specifications |
Heat Output ( BTU/HR ) |
42.7 |
MTBF ( Hours )* |
105,368 |
Operating Temperature |
-40C ambient for 16 hours and +70C ambient for 16 hours without use of fans |
Storage Temperature |
-40C to 85C, -40F to 185F |
Humidity |
5 to 95% (non condensing) for both storage and operation. |
Case |
SECC Zinc plated sheet metal (1 mm) |
Ingress Protection Rating |
IP30 |
Mounting |
1U - 19" rack, front and rear mounting hardware included.
DIN Rail mounting kit optional |
Product Weight and Dimensions |
Weight |
3.40 kg |
Dimensions |
1U Rack form factor - 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in) |
Packaging |
Shipping Dimensions |
59 x 36 x 9 (cm), 23 x 14 x 3.5 (in) |
Shipping Weight |
4.20 kg |
Regulatory Approvals |
Emissions |
Power Line conducted: IEC 61850-3 Sec 5.8, IEC 61000-6-4, CISPR 16-2-3, CISPR 22,
FCC Part 15, Subpart B, Class B |
Telecom Line conducted: IEC 61000-6-4, CISPR 22 |
Radiated: IEC 61850-3 Sec 5.8, IEC 61000-6-4, CISPR 16-2-3, CISPR 22, FCC Part 15, Subpart B, Class B |
IEC61000-3-2 Harmonic Current Emissions |
IEC61000-3-3 Flicker emissions |
EMC Interface Immunity
- IEC 61850-3 ( substations )
- IEEE 1613 ( substations ) (C37.90.x )
Applies to all ports, signal and power connections |
ESD: IEC61000-4-2, 8Kv Contact / 15Kv Air |
Radiated RFI: IEC61000-4-3, 20 V/m ( 80M-1G ) |
Fast Transients / Burst: IEC61000-4-4, 4Kv Mains , I/O |
Surge : IEC61000-4-5
4Kv AC line to Gnd, 2Kv AC Line to Line,
2Kv DC line to Gnd, 1 Kv DC Line to Line,
RS232 = balanced, ethernet = unbalanced |
Conducted RF: IEC61000-4-6, 10 Vrms |
Magnetic Field: IEC61000-4-8, 100 A/m, 1000 A/m (1 sec) |
Dips and Interrupts: IEC61000-4-11, Criteria A/B/C |
Oscillatory: EN61000-4-12, 2.5Kv common and differential mode |
Low Frequency conducted: EN61000-4-16, 30V 60s, 300V 1s,15Hz-150KHz @ level 3 |
Standard Safety Certifications |
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme. |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component) |
Other |
Reach, RoHS and WEEE Compliant |
CCATS - G052929 |
ECCN - 5A992A |
HTSUS Number: 8471.80.1000 |
Perle Lifetime Warranty |
Serial Connector Pinout |
IOLAN DTE
RJ45 Socket |
IOLAN RJ45 Socket |
Direction |
RS232 |
RS422 |
RS485 Full Duplex |
RS485 Half Duplex |
1 |
|
RTS |
TXD+ |
TXD+ |
Data+ |
2 |
|
DTR |
|
|
|
3 |
|
TXD |
TXD- |
TXD- |
Data- |
4 |
--- |
GND |
GND |
GND |
GND |
5 |
--- |
GND |
GND |
GND |
GND |
6 |
|
RXD |
RXD+ |
RXD+ |
|
7 |
|
DSR |
|
|
|
8 |
|
CTS |
RXD- |
RXD- |
|
A "rolled" CAT5 cable will automatically perform DTE to DCE crossover
|