CP-114UL-I-DB25M - 4 Port UPCI Board, w/DB25M Cable, RS-232/422/485, w/Isolation, Low Profile by MOXA
|
|
|
- Over 700 kbps data throughput for top performance
- 128-byte FIFO and on-chip H/W, S/W flow control
- Universal PCI compatible with 3.3/5 V PCI and PCI-X
- Serial communication speed up to 921.6 kbps
- Drivers provided for a broad selection of operating systems, including the latest Windows and Linux
- Easy maintenance with on-board LED display
- Wide temperature model available for -40 to 85°C environments
|
|
|
Moxa’s CP-114UL series of multiport serial boards are designed to be used by industrial automation system integrators for long distance, multi-point, PC-based data acquisition applications. On-chip Automatic Data Direction Control for precision RS-485 communication requires precise timing control to enable and disable the line driver. The Moxa Turbo Serial EngineTM chip that powers the CP-114UL/UL-I boards come with on-chip ADDC®, which makes RS-485 as easy to use as RS-232. In RS-485 mode, the serial port can connect up to 31 daisy-chained RS-485 devices within a range of 1.2 km. For long distance RS-485 communication, 2 kV electrical isolation protections are available to prevent equipment damage.
Drivers Provided for Windows, Linux, and Unix
Moxa continues to support a wide variety of operating systems, and the CP-114UL/UL-I boards are no exception. Reliable Windows COM and Linux/Unix TTY drivers are provided for all Moxa boards, and other operating systems, such as WEPOS, are also supported for embedded integration.
• Hardware |
Comm. Controller |
MU860 (16C550C compatible) |
Bus |
32-bit Universal PCI |
Connector |
DB44 female |
• Serial Interface |
Number of Ports |
4 |
Serial Standards |
RS-232/422/485 |
Max. No. of Boards per PC |
8 |
Electrical Isolation |
2 kV (CP-114UL-I only) |
• Performance |
Baudrate |
50 bps to 921.6 kbps (supports non-standard baudrates) |
• Serial Communication Parameters |
Data Bits |
5, 6, 7, 8 |
Stop Bits |
1, 1.5, 2 |
Parity |
None, Even, Odd, Space, Mark |
Flow Control |
RTS/CTS, XON/XOFF, RTS Toggle (RS-232 only) |
• Serial Signals |
RS-232 |
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 |
TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
RS-485-4w |
TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
RS-485-2w |
Data+(B), Data-(A), GND |
• Physical Characteristics |
Dimensions |
CP-114UL: 64.4 x 120 mm (2.53 x 4.72 in)
CP-114UL-I: 64.4 x 130 mm (2.53 x 5.12 in) |
• Driver Support |
Windows |
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows Server 2008 R2/2012/2012 R2/2016 (x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded |
Linux |
Linux 2.4.x, 2.6.x, 3.x |
Unix-like Systems |
QNX 6, SCO OpenServer, UnixWare 7, Solaris 10, FreeBSD |
Note |
Please refer to Moxa’s website for the latest driver support information. |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
EMC |
EN 55032/24 |
EMI |
CISPR 32, FCC Part 15B Class B |
EMS |
CP-114UL:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
CP-114UL-I:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4- |
• MTBF (mean time between failures) |
Time |
114,223 hrs |
Standard |
Telcordia (Bellcore) SR-332 |
• Power Requirements |
Input Current |
CP-114UL: 320 mA @ 5 VDC
CP-114UL-I: 465 mA @ 5 VDC |
|
|