RSM-405-R is a 5-port Real-time industrial-grade switch that was designed specifically to meet Railway Standards. It has 10/100 Base-T(X) Ethernet connectivity with auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection. It has a din rail mount. Solid industrial-grade design assures reliable operation in common application areas like: railway applications, semi-conductor factories, inventory control environments, assembly lines, manufacturing and many more. It supports an operating termperature range of -30C° ~ 75°. It meets EMC Emission, Immunity and Vibration standards. This permits them to be functional in very harsh environments.
Specifications |
Technology |
Standards |
IEEE 802.3, 802.3u, 802.3x |
Processing Type |
Store & forward |
MAC Addresses |
1024 |
Memory Bandwidth |
3.2 Gbps |
Frame buffer memory |
512 Kbit |
Flow Control |
IEEE802.3x flow control, back pressure flow control |
Interface |
RJ45 ports |
10/100 Base-T(X) auto negotiation speed, F/H duplex mode,
and auto MDI/MDI-X connection |
Dielectric I/O to Frame |
1500 VDC 1 minute |
MMI (Man Machine Interface) |
LED Indicators |
Master, Power, 10/100M, Link/Act |
Rotary Switch |
Recovery time setting |
DIP Switch |
Switch configuration |
Redundant Power Input |
Input Voltage Range |
+12 ~ +48 VDC |
Power consumption |
0.3A@24 VDC |
Reverse polarity protect |
Yes |
Dielectric I/O to Frame |
1500 VDC 1 minute |
Connection |
5-Pin Removable Terminal Block(5.08mm) |
Mechanical |
Case |
Metal |
Dimensions |
25 mm x 168 mm x 119 mm (W x L x H) |
Installation |
DIN-Rail |
Temperature/Humidity |
Operating Temperature |
-30 ~ +75°C; Cooling Test (IEC 60571), Dry Heat Test (IEC 60571) |
Storage Temperature |
-40 ~ +85°C |
Ambient Relative Humidity |
10% ~ 90% HR, non-condensing |
EMC Emission |
Conducted Emissions |
EN 50121-3-2, EN55011 |
Radiated Emissions |
EN 50121-3-2, EN55011 |
EMC Immunity |
Electrostatic Discharge |
EN 50121-3-2, IEC61000-4-2 |
Radiated, Radio-Frequency, Electromagnetic Field |
EN 50121-3-2, IEC61000-4-3 |
Electrical Fast Transient/Burst |
EN 50121-3-2, IEC61000-4-4 |
Surges |
EN 50121-3-2, IEC61000-4-5, IEC 60571 |
Conducted Disturbance Induced by Radio-Frequency Field |
EN 50121-3-2, IEC61000-4-6 |
Vibrations |
Random Vibration test |
IEC 61373 |
Shock Testing |
IEC 61373 |
|