Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
NPort IA-5150-M-ST - 1 RS-232/422/485 port to 1 100BaseF(X) multi-mode port, ST, IECEx, 0 to 60 Degree C operating temperature by MOXA

NPort IA-5150-M-ST - 1 RS-232/422/485 port to 1 100BaseF(X) multi-mode port, ST, IECEx, 0 to 60 Degree C operating temperature
by MOXA

Write a review Write a review
  •  Socket modes: TCP server, TCP client, UDP
  •  Patented ADDC® (Automatic Data Direction Control) for 2-wire and 4-wire RS-485
  •  Cascading Ethernet ports for easy wiring (applies only to RJ45 connectors)
  •  Redundant DC power inputs
  •  Warnings and alerts by relay output and email
  •  10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC connector)
  •  IP30-rated housing

 

Mfg SKU # : NPort IA-5150-M-ST
Our Price : $475.35
Stock : Call for Availability
Quantity :
NPort IA-5150-M-ST_DESCRIPTION

NPort IA-5150-M-ST is NPort® IA device servers provide easy and reliable serial-to-Ethernet connectivity for industrial automation applications. The device servers can connect any serial device to an Ethernet network, and to ensure compatibility with network software, they support a variety of port operation modes, including TCP Server, TCP Client, and UDP. The rock-solid reliability of the NPort® IA device servers makes them an ideal choice for establishing network access to RS-232/422/485 serial devices such as PLCs, sensors, meters, motors, drives, barcode readers, and operator displays. All models are housed in a compact, rugged housing that is DIN-rail mountable.

Cascading Ethernet Ports Make Wiring Easy (10/100BaseTX models)

The NPort® IA5150 and IA5250 device servers each have two Ethernet ports that can be used as Ethernet switch ports. One port connects directly to the network or server, and the other port can be connected to either another NPort® IA device server or an Ethernet device. The dual Ethernet ports help reduce wiring costs by eliminating the need to connect each device to a separate Ethernet switch.

Redundant Power Inputs

The NPort® IA5000 device servers have two power inputs that can be connected simultaneously to live DC power sources. If one power source fails, the other source takes over automatically. Redundant power inputs help assure that your device server will operate nonstop.

Relay Output Warning and Email Alerts

The built-in relay output can be used to alert administrators of problems with the Ethernet links or power inputs, or when there is a change in the DCD or DSR serial signals. The web console indicates which Ethernet link or power input has failed, or which serial signal has changed. An email warning can also be issued when an exception is detected. These functions are valuable tools that enable maintenance engineers to react promptly to emergency situations.

Optical Fiber for Ethernet Communication

The NPort® IA5000 Series includes 100BaseFX fiber models that support transmission distances up to 5 km for multi-mode models, and up to 40 km for single-mode models. Optical fiber is well-suited for industrial applications because it is immune to electromagnetic noise and interference. For environments that experience high ground loop voltages, fiber provides the best isolation protection, and because there is no danger of sparking, optical fiber is safer than copper wire to use in hazardous environments.

Industrial-grade Certification

To ensure safe and reliable operation in industrial environments, the NPort® IA5000 device servers have obtained various industrial certifications, including an IP30 rating for mechanical protection, UL 508 safety certification for industrial control equipment, and explosion-safe certifications for hazardous locations. Certifications include UL/cUL Class 1 Division 2 Groups A, B, C, D, as well as ATEX Class 1 Zone 2, and IECEx Zone 2.

Ethernet Interface

  • 10/100BaseT(X) Ports (RJ45 connector)

    2 (1 IP, Ethernet cascade, NPort IA-5150/5150I/5250/5250I)

  • Magnetic Isolation Protection

    1.5 kV (built-in)

  • 100BaseFX Ports (multi-mode SC connector)

    NPort IA-5000-M-SC Models: 1
    NPort IA-5000-M-ST Models: 1

  • 100BaseFX Ports (single-mode SC connector)

    NPort IA-5000-S-SC Models: 1

  • Optical Fiber

Ethernet Software Features

  • Configuration Options

    Web Console (HTTP), Windows Utility, Telnet Console, Serial Console

  • Management

    DHCP Client, IPv4, SMTP, SNMPv1, Telnet, ARP, BOOTP, DNS, HTTP, TCP/IP, UDP, ICMP, Rtelnet

  • Windows Real COM Drivers

    Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded

  • Linux Real TTY Drivers

    Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x

  • Fixed TTY Drivers

    SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X, macOS 10.12, macOS 10.13, macOS 10.14, macOS 10.15

  • Android API

    Android 3.1.x and later

  • Time Management

    SNTP

  • MIB

    RFC1213, RFC1317

Serial Interface

  • Connector

    NPort IA-5150: DB9 male for RS-232 and terminal block for RS-422/485
    NPort IA-5250: DB9 male for RS-232/422/485

  • No. of Ports

    NPort IA-5150 Models: 1
    NPort IA-5250 Models: 2

  • Serial Standards

    RS-232, RS-422, RS-485

  • Baudrate

    Supports standard baudrates (unit=bps): 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230400

  • Data Bits

    5, 6, 7, 8

  • Parity

    None, Even, Odd, Space, Mark

  • Stop Bits

    1, 1.5, 2

  • Flow Control

    RTS/CTS (RS-232 only), DTR/DSR (RS-232 only), XON/XOFF

  • Terminator for RS-485

    120 ohms

  • Pull High/Low Resistor for RS-485

    1 kilo-ohm, 150 kilo-ohms

  • Isolation

    2 kV (I models)

  • RS-485 Data Direction Control

    ADDC® (automatic data direction control)

Serial Signals

  • RS-232

    TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

  • RS-422

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    Data+, Data-, GND

Power Parameters

  • Input Voltage

    12 to 48 VDC

  • Input Current

    NPort IA-5150/IA-5150-T/IA-5250/IA-5250-T: 435 mA @ 12 VDC
    NPort IA-5150I/IA-5150I-T/IA-5150-S-SC/IA-5150-S-SC-T/IA-5150I-M-SC/IA-5150I-M-SC-T/IA-5150I-S-SC/IA-5150I-S-SC-T: 555 mA @ 12 VDC
    NPort IA-5250I/IA-5250I-T/IA-5150-M-SC/IA-5150-M-SC-T/IA-5150-M-ST/IA-5150-M-ST-T: 510 mA @ 12 VDC

  • No. of Power Inputs

    2

  • Power Connector

    Terminal block

Relays

  • Contact Current Rating

    Resistive load: 1 A @ 30 VDC

Physical Characteristics

  • Housing

    Plastic

  • IP Rating

    IP30

  • Dimensions

    29 x 89.2 x 118.5 mm (0.82 x 3.51 x 4.57 in)

  • Weight

    NPort IA-5150: 360 g (0.79 lb)
    NPort IA-5250: 380 g (0.84 lb)

  • Installation

    DIN-rail mounting

Environmental Limits

  • Operating Temperature

    Standard Models: 0 to 60°C (32 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 167°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

Standards and Certifications

  • EMC

    EN 55032/35

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF
    IEC 61000-4-11

  • Safety

    IEC 60950-1, EN 60950-1, EN 62368-1, UL 508

  • Maritime

    DNV

  • Hazardous Locations

    ATEX, Class I Division 2, IECEx

  • Freefall

    IEC 60068-2-32

  • Shock

    IEC 60068-2-27

  • Vibration

    IEC 60068-2-6, IEC 60068-2-64

Declaration

  • Green Product

    RoHS, CRoHS, WEEE

MTBF

  • Time

    NPort IA-5150/IA-5150I Models: 1,349,710 hrs
    NPort IA-5150-M-SC/M-ST/S-SC Models: 1,175,887 hrs
    NPort IA-5150I-M-SC Models 768,343 hrs
    NPort IA-5150I-S-SC Models: 763,707 hrs
    NPort IA-5250/IA-5250I Models: 1,236,384 hrs

  • Standards

    Telcordia (Bellcore) Standard TR/SR


Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.